Usefulness of a New Gelatin Glue Sealant System for Dural Closure in a Rat Durotomy Model

نویسندگان

  • Hisashi KAWAI
  • Ichiro NAKAGAWA
  • Fumihiko NISHIMURA
  • Yasushi MOTOYAMA
  • Young-Su PARK
  • Mitsutoshi NAKAMURA
  • Hiroyuki NAKASE
  • Shuko SUZUKI
  • Yoshito IKADA
چکیده

Watertight dural closure is imperative after neurosurgical procedures, because inadequately treated leakage of cerebrospinal fluid (CSF) can have serious consequences. We used a rat durotomy model to test the usefulness of a new gelatin glue as a dural sealant in a rat model of transdural CSF leakage. All rats were randomly divided into one of the following three treatment groups: no application (control group: N = 18), application of fibrin glue (fibrin glue group: N = 18), and application of the new gelatin glue (new gelatin glue group: N = 18). The craniotomy side was re-opened, and CSF leakage was checked and recorded at 1, 7, and 28 days postoperatively. The new gelatin glue was adequate for stopping CSF leakage; no leakage was observed at postoperative days 1 or 7, and leakage was observed in only one rat at postoperative day 28. This result was statistically significant when compared to the control group (P = 0.002, P = 0.015, P = 0.015, respectively). The pathologic score of the new gelatin group was not different from that of the control or fibrin glue groups. We conclude that our new gelatin glue provides effective watertight closure 1, 7, and 28 days after operation in the rat durotomy model.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adherus Dural Sealant as an Adjunct to Sutured Dural Repair in a Canine Cranial Durotomy Repair Model

The objective of this study was to evaluate the safety and effectiveness of Adherus Dural Sealant when used as an adjunct to sutures in dural closure in a canine durotomy repair model. The effectiveness was evaluated at time of surgery, Day 8 and again at approximately 6 months by pressure testing. The safety and endurance of the test article was evaluated over approximately six months using ma...

متن کامل

Adherus Dural and Spinal Sealant as Adjuncts to Sutured Dural Repair in a Canine Lumbar Durotomy Repair Model

The objective of this GLP study was to evaluate the safety and effectiveness of Adherus Dural Sealant and Adherus Spinal Sealant when used to achieve watertight dural closure in a canine lumbar durotomy repair model. Another important objective of this study was to determine whether Adherus Dural and Adherus Spinal Sealants would inhibit the formation of peridural fibrosis and dural adhesions a...

متن کامل

The Application of a New Cyanoacrylate Glue in Pediatric Surgery for Fistula Closure

Surgical glues have been used in pediatric surgery because of the fragility of tissue, and to prevent major surgeries. The present report describes our experience with using a new cya-noacrylate Glubran 2 (Viareggio, Italy) in the treatment of five cases of tracheoesophageal atresia with fistula (one fistula protection, three recurrent fistula, and one unstable patients), two cases of hypospadi...

متن کامل

Delayed Cerebrospinal Fluid Leak after Watertight Dural Closure with a Polyethylene Glycol Hydrogel Dural Sealant in Posterior Fossa Surgery: Case Report

A polyethylene glycol (PEG) hydrogel sealant recently has been approved as an adjunct to sutured dural closure in Japan. We treated consecutive six patients with PEG hydrogel sealant in posterior fossa operation. Three of six cases suffered delayed cerebrospinal fluid (CSF) leak after watertight dural closure with the PEG hydrogel sealant, although there was no leak case which was treated with ...

متن کامل

A multicenter, single-blind, prospective randomized trial to evaluate the safety of a polyethylene glycol hydrogel (Duraseal Dural Sealant System) as a dural sealant in cranial surgery.

OBJECTIVE Incisional cerebrospinal fluid (CSF) leakage after cranial surgery is a significant cause of morbidity due to poor wound healing and infection, meningitis, and pseudomeningocele formation. Many common dural closure techniques, such as sutures, autologous grafts, gelatin or collagen sponges, and fibrin glues, are used to achieve watertight closure, although none are US Food and Drug Ad...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 54  شماره 

صفحات  -

تاریخ انتشار 2014