Automatic generation control of power system using a novel quasi-oppositional harmony search algorithm

نویسندگان

  • Chandan Kumar Shiva
  • G. Shankar
  • V. Mukherjee
چکیده

The present work approaches a novel quasi-oppositional harmony search (QOHS) algorithm, as an optimization technique, for its optimum performance in the subject area of automatic generation control (AGC) of power system. The proposed QOHS algorithm is applied with an aim to converge rapidly towards the optimal solution(s) that houses both the characters of two guesses, i.e. opposite-point and quasi-opposite point. The area of concern of this study is to discuss the multi-objective problems of an interconnected power system for the benefits of AGC. The proposed QOHS algorithm is, individually, applied to single-area, precede to two-area considering the non-linearity effects of governor dead band and generation rate constraint and, finally, extended to four-area power system showing the consequences of multiple load disturbances. A case of robustness and stability analysis are also investigated for the studied two-area power system model. The control strategy, for the dynamic power system model, is based on area control error. The simplicity of the structure and acceptability responses of the well-known proportional–integral–derivative controller enforces to implement as a controller in this work. The comparative evaluation of the proposed QOHS algorithm is carried out by the way of comparing the dynamic performances of the studied power systemmodel with those offered by other algorithms reported in the recent state-of-the-art literature. The simulation works, presented in the paper, reveal that the proposed QOHS algorithm may be effectively utilized for the purpose of AGC study of power system having varying degrees of complexities and non-linearities. Moreover, the proposed QOHS based control strategy adopted in this work provides a robust and stable speed control mechanism. 2015 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Load Model Effect Assessment on Optimal Distributed Generation Sizing and Allocation Using Improved Harmony Search Algorithm

The operation of a distribution system in the presence of distributed generation systems has someadvantages and challenges. Optimal sizing and siting of DG systems has economic, technical, andenvironmental benefits in distribution systems. Improper selection of DG systems can reduce theseadvantages or even result in deterioration in the normal operation of the distribution system. DGallocation ...

متن کامل

Studying Impact of Unified Power Flow Controller on improve transient stability by Improved Harmony Search Algorithm

Main contribution of this work is improving transient stability by installing Flexible AC Transmission System (FACTS) in power systems. For do this, Unified Power Flow Controller (UPFC) has been selected. Also a novel structure has been suggested to improve classic Harmony Search algorithm and suggested improved Harmony Search (iHS) algorithm. This algorithm has been used to obtain UPFC paramet...

متن کامل

Studying Impact of Unified Power Flow Controller on improve transient stability by Improved Harmony Search Algorithm

Main contribution of this work is improving transient stability by installing Flexible AC Transmission System (FACTS) in power systems. For do this, Unified Power Flow Controller (UPFC) has been selected. Also a novel structure has been suggested to improve classic Harmony Search algorithm and suggested improved Harmony Search (iHS) algorithm. This algorithm has been used to obtain UPFC paramet...

متن کامل

Optimizing the AGC system of a three-unequal-area hydrothermal system based on evolutionary algorithms

This paper focuses on expanding and evaluating an automatic generation control (AGC) system of a hydrothermal system by modelling the appropriate generation rate constraints to operate practically in an economic manner. The hydro area is considered with an electric governor and the thermal area is modelled with a reheat turbine. Furthermore, the integral controllers and electri...

متن کامل

Multi-Stage Fuzzy Load Frequency Control Based on Multi-objective Harmony Search Algorithm in Deregulated Environment

A new Multi-Stage Fuzzy (MSF) controller based on Multi-objective Harmony Search Algorithm (MOHSA) is proposed in this paper to solve the Load Frequency Control (LFC) problem of power systems in deregulated environment. LFC problem are caused by load perturbations, which continuously disturb the normal operation of power system. The objectives of LFC are to mini small size the transient deviati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016