High Voltage Ride Through with FACTS for Wind Turbines with Doubly Fed Induction Generator

نویسندگان

  • C. Wessels
  • F. W. Fuchs
چکیده

In future grid codes wind farms will have to fulfill demanding fault ride through requirements. Among several grid faults the voltage swell is a critical event. Wind farms with doubly-fed induction generators will not be able to fulfill the new grid code requirements without additional fault mitigation equipment. In this publication the applicability of the Dynamic Voltage Restorer and the Static Synchronous Compensator to mitigate a three phase voltage swell without phase angle variation at a wind turbine is investigated and compared. The mitigation equipment adds the missing high voltage ride through capability to the wind energy system in order to become grid compliant. The function, control structure and design and the performance is presented and verified by simulations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low Voltage Ride-Through Capability Improvement of Doubly Fed Induction Generator using DVR and SMES

Abstract: With the growth of communities and the increasing need for electricity, and because of the many benefits of renewable energy sources, the wind turbine has become a completely commercial and inevitable process, with increasing penetration into the electricity grid. Distribution networks, on the other hand, are subject to fault that cause power fluctuations and outflow of wind units. In...

متن کامل

A New Method to Enhance the Low Voltage Ride Through Capability of Doubly Fed Induction Generator Using Resistive Type Superconducting Fault Current Limiter

In the event of voltage sag at the nearing of a wind park, severe currents may pass through the power electronic devices of the Doubly Fed Induction Generators (DFIGs). Hence, according to the Low Voltage Ride Through (LVRT) requirements, the wind parks are allowed to disconnect from the network after a certain time. Therefore, to avoid such actions, the LVRT requirement of wind parks is consid...

متن کامل

Unbalanced-Grid-Fault Ride-Through Control for a Doubly Fed Induction Generator Wind Turbine with Series Grid-Side Converter

The grid codes now require doubly fed induction generator (DFIG) wind turbines having the “low voltage ride-through (LVRT)” capability. However, a traditional DFIG with a partially rated back-to-back converter has inherent difficulties to ride through the grid faults, especially for the unbalanced grid faults. Modifications to the traditional DFIG configuration for ride-through have become nece...

متن کامل

Low Voltage Ride Through Enhancement Based on Improved Direct Power Control of DFIG under Unbalanced and Harmonically Distorted Grid Voltage

In the conventional structure of the wind turbines along with the doubly-fed induction generator (DFIG), the stator is directly connected to the power grid. Therefore, voltage changes in the grid result in severe transient conditions in the stator and rotor. In cases where the changes are severe, the generator will be disconnected from the grid and consequently the grid stability will be attenu...

متن کامل

GA-Based Optimal LQR Controller to Improve LVRT Capability of DFIG Wind Turbines

Nowadays, the doubly-fed induction generators (DFIGs) based wind turbines (WTs) are the dominant type of WTs connected to grid. Traditionally the back-to-back converters are used to control the DFIGs. In this paper, an Indirect Matrix Converter (IMC) is proposed to control the generator. Compared with back-to-back converters, IMCs have numerous advantages such as: higher level of robustness, re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009