Intersession Repeatability of Acoustic Rhinometry Measurements in Healthy Volunteers

نویسندگان

  • Mohammed Dhafer Al Ahmari
  • Jadwiga Anna Wedzicha
  • John Robert Hurst
چکیده

OBJECTIVES Acoustic rhinometry is a rapid, reliable and non-invasive technique for the evaluation of conditions associated with impaired nasal patency. This study aimed to examine the intersession repeatability of acoustic rhinometry measurements of unilateral and combined nasal parameters in a group of healthy volunteers. METHODS Twenty healthy volunteers were studied. In each subject, acoustic rhinometry measurements were performed on five consecutive days, with multiple recordings. Five clinically relevant parameters were measured in each session and the intersession repeatability of these measurements was expressed in terms of mean coefficient of variation, intraclass correlation coefficient and inter-item correlations. RESULTS Intraclass correlation coefficients showed a high, and greater repeatability over time for all the combined (mean) values compared to the unilateral values. All intraclass correlations for combined values were ≥0.80 confirming almost perfect agreement. All intraclass correlations and inter-item correlations were associated with P<0.001. The mean coefficient of variation was low (<10%) for all but the proximal minimum cross sectional area (MCA1) measurements. CONCLUSION Acoustic rhinometry provides highly repeatable measurements of nasal patency, which is best for combined (mean) nasal parameters. This property makes it suitable for use in the diagnosis and follow-up of conditions associated with nasal obstruction, either structural or functional.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Nasal Obstruction after Different Nasal Surgeries Using Acoustic Rhinometry and Nasal Obstruction Symptom Evaluation Scale

BACKGROUND The efficiency of nasal surgeries can be determined by objective or subjective methods. We have assessed the effect of nasal obstruction after different nasal surgeries using Acoustic Rhinometry (AR) and Nasal Obstruction Symptom Evaluation (NOSE) Scale. METHODS Between May 2011 and May 2012, 40 young adult patients and 10 healthy volunteers as control group who referred to ...

متن کامل

Repeatability of aberrometric measurements with a new instrument for vision analysis based on adaptive optics.

PURPOSE To evaluate intersession and intrasession repeatability of aberration data obtained with a new visual simulator based on adaptive optics, which includes a Hartmann-Shack aberrometer (Adaptive Optics Vision Analyzer; Voptica S.L., Murcia, Spain). METHODS Thirty-one healthy right eyes were included in the study. To evaluate intrasession repeatability, three consecutive measurements with...

متن کامل

Reliability of noncontact pachymetry after laser in situ keratomileusis.

PURPOSE To assess the repeatability and reproducibility of central corneal thickness (CCT) measurements obtained by combined scanning-slit/Placido-disc topography (Orbscan II; Bausch & Lomb, Rochester, NY) after laser in situ keratomileusis (LASIK) and to compare the results with another noncontact method, specular microscopy (SP-2000P; Topcon, Tokyo, Japan). METHODS To analyze intrasession r...

متن کامل

Modelling the reproducibility of acoustic rhinometry.

This paper presents an application of a linear model with correlated errors to the assessment of the precision of acoustic rhinometry in clinical medicine. The design of the reproducibility study involved 20 healthy subjects measured by five investigators with three replicate measurements of four variates taken from the right and left nasal cavities, altogether 2400 measurements. The parametric...

متن کامل

Precision and Agreement of Corneal Power Measurements Obtained Using a New Corneal Topographer OphthaTOP

PURPOSE To evaluate repeatability and reproducibility of anterior corneal power measurements obtained with a new corneal topographer OphthaTOP (Hummel AG, Germany) and agreement with measurements by a rotating Scheimpflug camera (Pentacam HR, Oculus, Germany) and an automated keratometer (IOLMaster, Carl Zeiss Meditec, Germany). METHODS The right eyes of 79 healthy subjects were prospectively...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2012