Intrarater and interrater reliability of the MS functional composite outcome measure.

نویسندگان

  • J A Cohen
  • J S Fischer
  • D M Bolibrush
  • A J Jak
  • J E Kniker
  • L A Mertz
  • T T Skaramagas
  • G R Cutter
چکیده

OBJECTIVE To assess practice effects, and intrarater and interrater reliability of the MS functional composite (MSFC) outcome measure. BACKGROUND To address the poor reliability and insensitivity to change of available MS clinical rating scales, the National MS Society's Clinical Outcomes Assessment Task Force developed the MSFC, a multidimensional quantitative clinical outcome measure that includes tests of leg function/ambulation (Timed 25-Foot Walk), arm function (Nine-Hole Peg Test), and cognitive function (Paced Auditory Serial Addition Test). METHODS Ten patients with secondary progressive MS underwent six testing sessions over a 2-week period. The MSFC was administered by the same examining technician in the first five sessions and by the other technician in the sixth. Patients were reassessed by both technicians after 6 months (sessions 7 and 8). The MSFC score was calculated as the mean of the Z scores of the three components. A pooled dataset derived from secondary progressive MS patients in the placebo arms of previous clinical trials and natural history studies served as the reference population to standardize scores. RESULTS Practice effects were evident initially but stabilized by the fourth administration. The intraclass correlation coefficient (ICC) was 0.97 for the MSFC for session 4 versus session 5 (intrarater reliability). The ICC was 0.95 for session 5 versus session 6 (interrater reliability), and was 0.96 for session 7 versus session 8 when patients were reassessed 6 months later. CONCLUSIONS The MS functional composite (MSFC) outcome measure had excellent intrarater and interrater reliability when standardized procedures were used to train examining technicians and to assess patients. Prebaseline testing sessions should be included in clinical trials employing the MSFC to compensate for practice effects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intrarater and interrater reliability of the Anteromedial Reach Test in healthy participants

BACKGROUND The Anteromedial Reach Test is a performance-based outcome measure for evaluating dynamic knee stability in patients with anterior cruciate ligament injury. No previously published study has adequately evaluated intrarater or interrater reliability of the Anteromedial Reach Test, so the purpose of this study was to assess these measurement properties in healthy participants prior to ...

متن کامل

Reliability of first ray position and mobility measurements in experienced and inexperienced examiners.

CONTEXT Neither reliability nor validity data exist for the Root method of clinically assessing first ray position or mobility by experienced and inexperienced examiners. OBJECTIVE To determine intrarater and interrater reliability for first ray position and mobility measurements in experienced and inexperienced examiners. DESIGN Single-blind prospective reliability study. SETTING Physica...

متن کامل

Intrarater and interrater reliability of 22 clinical measures associated with lower quarter malalignment.

OBJECTIVE The purpose of this study was to assess the intrarater and interrater reliability of a broad range of techniques commonly used to assess the lower quarter. METHODS A test-retest single group design was used to investigate the intrarater and interrater reliability of 22 lower quarter evaluation measures. Two raters conducted each measure twice on a total of 18 unimpaired subjects wit...

متن کامل

Reliability of the visual assessment of cervical and lumbar lordosis: how good are we?

STUDY DESIGN Blinded test-retest design. OBJECTIVE To measure the intrarater and interrater reliability of the visual assessment of cervical and lumbar lordosis. SUMMARY OF BACKGROUND DATA Cervical and lumbar lordoses are frequently evaluated using visual assessment, but little attempt has previously been made to measure the reliability of visual assessment. METHODS Twenty-eight chiroprac...

متن کامل

Reliability and limits of agreement of circumferential, water displacement, and optoelectronic volumetry in the measurement of upper limb lymphedema.

We conducted a reliability comparison study to determine the intrarater and inter-rater reliability and the limits of agreement of the volume estimated by circumferential measurements using the frustum sign method and the disk model method, by water displacement volumetry, and by infrared optoelectronic volumetry in the assessment of upper limb lymphedema. Thirty women with lymphedema following...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Neurology

دوره 54 4  شماره 

صفحات  -

تاریخ انتشار 2000