Prognostic importance of defibrillator shocks in patients with heart failure.

نویسندگان

  • Jeanne E Poole
  • George W Johnson
  • Anne S Hellkamp
  • Jill Anderson
  • David J Callans
  • Merritt H Raitt
  • Ramakota K Reddy
  • Francis E Marchlinski
  • Raymond Yee
  • Thomas Guarnieri
  • Mario Talajic
  • David J Wilber
  • Daniel P Fishbein
  • Douglas L Packer
  • Daniel B Mark
  • Kerry L Lee
  • Gust H Bardy
چکیده

BACKGROUND Patients with heart failure who receive an implantable cardioverter-defibrillator (ICD) for primary prevention (i.e., prevention of a first life-threatening arrhythmic event) may later receive therapeutic shocks from the ICD. Information about long-term prognosis after ICD therapy in such patients is limited. METHODS Of 829 patients with heart failure who were randomly assigned to ICD therapy, we implanted the ICD in 811. ICD shocks that followed the onset of ventricular tachycardia or ventricular fibrillation were considered to be appropriate. All other ICD shocks were considered to be inappropriate. RESULTS Over a median follow-up period of 45.5 months, 269 patients (33.2%) received at least one ICD shock, with 128 patients receiving only appropriate shocks, 87 receiving only inappropriate shocks, and 54 receiving both types of shock. In a Cox proportional-hazards model adjusted for baseline prognostic factors, an appropriate ICD shock, as compared with no appropriate shock, was associated with a significant increase in the subsequent risk of death from all causes (hazard ratio, 5.68; 95% confidence interval [CI], 3.97 to 8.12; P<0.001). An inappropriate ICD shock, as compared with no inappropriate shock, was also associated with a significant increase in the risk of death (hazard ratio, 1.98; 95% CI, 1.29 to 3.05; P=0.002). For patients who survived longer than 24 hours after an appropriate ICD shock, the risk of death remained elevated (hazard ratio, 2.99; 95% CI, 2.04 to 4.37; P<0.001). The most common cause of death among patients who received any ICD shock was progressive heart failure. CONCLUSIONS Among patients with heart failure in whom an ICD is implanted for primary prevention, those who receive shocks for any arrhythmia have a substantially higher risk of death than similar patients who do not receive such shocks.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Allograft vasculopathy vs. coronary artery disease: comparison by optical coherence tomography.

McNitt S, Andrews ML, Elkin AD. Long-term clinical course of patients after termination of ventricular tachyarrhythmia by an implanted defibrillator. Circulation 2004;110:3760–3765. 22. Poole JE, Johnson GW, Hellkamp AS, Anderson J, Callans DJ, Raitt MH, Reddy RK, Marchlinski FE, Yee R, Guarnieri T, Talajic M, Wilber DJ, Fishbein DP, Packer DL, Mark DB, Lee KL, Bardy GH. Prognostic importance o...

متن کامل

کاربرد مدل‌های نیمه‌پارامتری بقا در ارزیابی عوامل خطر وابسته به زمان بر نرخ شوک‌های واردشده به بیماران قلبی

Background: One of the treatments in patients with dangerous diseases particularly heart failure, is Implantable Cardioverter Defibrillator (ICD) that is used to prevent sudden cardiac death. Regarding to the superiority of ICD rather than medical treatment, the purpose of this study is the assessment of time-dependent effective factors on the rates of entered shocks to patients with ICD. ...

متن کامل

Prognostic impact of inappropriate defibrillator shocks in a population cohort.

BACKGROUND There is a relative paucity of data linking inappropriate implantable cardioverter-defibrillator (ICD) shocks to adverse clinical outcomes. OBJECTIVE To examine the association between inappropriate ICD shocks and mortality or heart transplantation in a large population cohort. DESIGN, SETTING, PATIENTS A cohort study which included all subjects who underwent ICD implantation bet...

متن کامل

Inappropriate implantable cardioverter-defibrillator shocks: incidence, predictors, and impact on mortality.

OBJECTIVES The purpose of this study was to assess the incidence, predictors, and outcome of inappropriate shocks in implantable cardioverter-defibrillator (ICD) patients. BACKGROUND Despite the benefits of ICD therapy, inappropriate defibrillator shocks continue to be a significant drawback. The prognostic importance of inappropriate shocks outside the setting of a clinical trial remains unc...

متن کامل

Arrhythmia Management Devices

1576 Implantable cardioverter defibrillators (ICDs) save lives in patients at risk for sudden death attributable to ventricular arrhythmias, pacemakers (PMs) have been improving symptoms in patients with bradyarrhythmias for decades, and, more recently, cardiac resynchronization devices have improved mortality, morbidity, and quality of life for patients with heart failure. However, these devic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The New England journal of medicine

دوره 359 10  شماره 

صفحات  -

تاریخ انتشار 2008