A Non-invasive Biopotential Electrode for the Correct Detection of Bioelectrical Currents

نویسندگان

  • C. Boccaletti
  • G. Fabbri
  • M. Santello
چکیده

An advanced current measure probe is described for biological applications. Singular points on the body skin emit a semi-constant current that could be potentially useful for a medical diagnosis of the body organs to which any singular point is connected. In order to achieve an accurate and reliable analysis of the emitted current, all the error sources have been studied in order to design a ready to use probe.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Bioelectrical Sensor for the Detection of Small Biological Currents

A novel instrumentation system has been designed for the correct detection of small dc currents emitted by characteristics points of the human skin using a non invasive probe. The probe presents an integrated pressure compensation system based on a force sensor allowing to obtain reliable and repeatable measurements that are virtually insensitive to pressure fluctuations. The current acquisitio...

متن کامل

Stator Turn-to-Turn Fault Detection of Induction Motor by Non-Invasive Method Using Generalized Regression Neural Network

Condition monitoring and protection methods based on the analysis of the machine's current are widely used according to non-invasive characteristics of current transformers. It should be noted that, these sensors are installed by default in the machine control center. On the other hand, condition monitoring based on mathematical methods has been proposed in literature. However, they are model b...

متن کامل

The effect of lead (Pb2+) on electrophysiological properties of calcium currents in F77 neuron in Helix aspersa

Ion channels are responsible for control of cell function in excitable tissues such as heart and brain and also in organs and tissues traditionally thought to be non- excitable including liver and epithelium. In the present research, the effect of lead (Pb2+) on Ca2+ -dependent action potential and currents was studied in F77 neuronal soma membrane of Helix aspersa. For this purpose, action pot...

متن کامل

Non - invasive Bio - impedance Measurement Using Voltage - Current Pulse Technique

Noninvasive detection is a fundamental prerequisite for pervasive healthcare system and biosensing. Along with different noninvasive techniques such as ultrasound, X-ray, magnetic resonance and optical imaging, electrical impedance spectroscopy is emerging as more suitable technique for tissue level diagnosis. This paper presents a noninvasive technique for bioelectrical impedance estimation by...

متن کامل

Nile Blue- Chitosan Composite as a new Electrochemical Sensor for Uric Acid on Glassy Carbon Electrode

Nile blue-Chitosan NB-CH as a new type of organic days-organic composite was made using Nile blue and chitosan. The NB-CH composite was made using a 0.005 M solution of Nile blue NB and a 7 solution of chitosan. To do this, a mixture of Nile blue and Chitosan with the ratio of 2:1 was prepared. The electrocatalytic oxidation of uric acid UA has been studied on glassy carbon electrode by NB-CH u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007