Energy non-linearity effects in the response of ionic crystal scintillators to X-rays with energy in the region of the K-absorptions edges: experimental results

نویسنده

  • L. F. Requicha Ferreira
چکیده

The response of a YAP, NaI(Tl) and BaF2 scintillators to X-rays with energies around the Y, I, and Ba K-absorption edges, respectively, was investigated. For all the scintillators, the amplitude response follows different linear trends for X-ray energies below and above the respective K-edges, presenting a discontinuity at these energies. An abrupt decrease of about 3%, 5% and 2% were observed in the detector amplitude at the K-edges, for the YAP, the NaI(Tl) and the BaF2 scintillator, respectively, corresponding to a decrease of 0.570.1, 1.770.3 and 0.870.2 keV in the energy calibration line. These discontinuities result in a region within 0.570.1, 1.670.3 and 0.970.2 keV where the X-ray energy cannot be obtained unambiguously. The scintillation yields for X-rays present abrupt decreases of about 3%, 4% and 2%, respectively, at the K-edges. The measured non-linearity effects are significantly larger than those obtained for gaseous and semiconductor detectors. The higher amplitude non–linearity observed in NaI(Tl) is attributed to the larger light yield non-linearity in the electron response of this crystal. r 2003 Elsevier B.V. All rights reserved. PACS: 07.85.Nc; 29.30.Kv; 29.40.Mc; 32.80.Hd; 32.80.t; 85.60.Jb

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

شبیه‌سازی تابع پاسخ سوسوزن‌های آلی به تابش گاما و نوترون با استفاده از کدهای مونت کارلوی FLUKA،MCNPX و SCINFUL

In organic scintillators, the energy distribution of gamma rays and neutrons is indirectly measured by the pulse height distribution of light output produced through gamma ray and neutron reactions in the detectors. Accurate estimate of the interaction of gamma and neutrons in the detector and produce charged secondary particles and subsequent scintillation light produced in the calculation of ...

متن کامل

Optical simulation and experimental measurement of gamma ray energy spectrum of plastic scintillators with different sizes

The application of large plastic scintillators is widely increasing in the different areas of industry, medicine and security due to technical and economic advantages. One of the main disadvantages of these detectors is the unknown position of Compton edge at gamma ray spectrum. In this research, GEANT4/GATE code has been used to simulate the gamma ray spectrum for different volumes of large pl...

متن کامل

An in-vivo study on the energy dependence of X-ray biological effectiveness

Background: The International Commission on Radiological Protection (ICRP) has attributed the same relative risk for X and gamma radiations of all energies. Several studies have proven that the biological effect of low energy photon is more than that of higher ones. The assessment of risks is important due to the wide use of low energy X-rays for mammography screening and other diagnostic appli...

متن کامل

A COMPARISON BETWEEN THERMAL AND X RADIOGRAPHY FOR STUDYING THE INTERNAL STRUCTURE OF BIOLOGICAL

 ABSTRACT Background: With respect to the difference in the interaction of thermal neutron and X rays with matter, using two radiography systems of thermal neutron and X rays will yield highly valuable information for studying the inner structure of biologic samples. Methods: The high sensitivity of thermal neutron to hydrogen, in particular, has led to recognizing this system as a useful tool ...

متن کامل

Investigating the effect of voltage fluctuations on the beam quality of X-rays in the range energy of diagnostic radiology

The purpose of this study was to investigate the effect of voltage ripple produced by X-ray machines on the quality of X-ray rays. For this purpose, the energy spectrum from the X-ray tube manufacturer should be simulated in the range of diagnostic radiography and verified by experimental results. The statistical analysis of the results showed that there is no significant difference between sim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003