3D myocardial T 1 mapping using saturation recovery

نویسندگان

  • Giovanna Nordio
  • Markus Henningsson
  • Amedeo Chiribiri
  • Adriana D.M. Villa
  • Torben Schneider
  • René M. Botnar
چکیده

PURPOSE To propose a 3D quantitative high-resolution T1 mapping technique, called 3D SASHA (saturation-recovery single-shot acquisition), which combines a saturation recovery pulse with 1D-navigator-based-respiratory motion compensation to acquire the whole volume of the heart in free breathing. The sequence was tested and validated both in a T1 phantom and in healthy subjects. MATERIALS AND METHODS The 3D SASHA method was implemented on a 1.5T scanner. A diaphragmatic navigator was used to allow free-breathing acquisition and the images were acquired with a resolution of 1.4 × 1.4 × 8 mm3 . For assessment of accuracy and precision the sequence was compared with the reference gold-standard inversion-recovery spin echo (IRSE) pulse sequence in a T1 phantom, while for the in vivo studies (10 healthy volunteers) 3D SASHA was compared with the clinically used 2D MOLLI (3-3-5) and 2D SASHA protocols. RESULTS There was good agreement between the T1 values measured in a T1 phantom with 3D SASHA and the reference IRSE pulse sequences (1111.6 ± 31 msec vs. 1123.6 ± 8 msec, P = 0.9947). Mean and standard deviation of the myocardial T1 values in healthy subjects measured with 2D MOLLI, 2D SASHA, and 3D SASHA sequences were 881 ± 40 msec, 1181.3 ± 32 msec, and 1153.6 ± 28 msec respectively. CONCLUSION The proposed 3D SASHA sequence allows for high-resolution free-breathing whole-heart T1 -mapping with T1 values in good agreement with the 2D SASHA and improved precision. LEVEL OF EVIDENCE 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:218-227.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Saturation recovery allows T1 mapping in the human heart at 7T with a commercial MRI scanner

Background Myocardial T1 mapping at 1.5T and 3T distinguishes powerfully between normal and diseased tissue with focal and diffuse pathology. We recently reported the first human myocardial T1s at 7T using the ShMOLLI +IE inversion recovery sequence. Yet even using a unique 7T scanner with 16kW RF output, perfect magnetization inversion was impossible. We now introduce a saturation recovery met...

متن کامل

Myocardial T1 mapping using SMART1Map: initial in vivo experience

Background Recently a single-point, saturation-recovery myocardial T1 mapping sequence (SMART1Map = Saturation Method using Adaptive Recovery Times for cardiac T1 Mapping) was presented [1]. Compared to common methods like MOLLI, SMART1Map measures true T1 instead of apparent T1 relaxation, is more time efficient and can track exact TI times instead of estimated ones based on the heart rate dur...

متن کامل

3D black-blood T1 mapping of the mouse heart using IntraGate FLASH and DESPOT1 analysis

Figure 5: T1 variation between slices. Values are mean ± SD Figure 1: 3D black-blood IntraGate FLASH sequence. A saturation slice on top of the heart creates a navigator echo that retrospectively triggers the subsequent 3D FLASH acquisition of the left ventricle. A representative geometry is shown. Figure 2: Comparison of T1 values (s) calculated from Saturation Recovery data and 3D IntraGate F...

متن کامل

3D saturation recovery imaging for free breathing myocardial T1 mapping

Background Longitudinal magnetization relaxation time (T1) mapping can overcome limitations of late gadolinium enhancement for the detection of diffuse fibrosis in the myocardium. Several T1 mapping methods have been proposed in recent years; however most of them are limited to 2D breath-hold acquisitions with associated limitations in signal-to-noise ratio (SNR) and spatial resolution. A MOdif...

متن کامل

Saturation pulse design for quantitative myocardial T1 mapping

BACKGROUND Quantitative saturation-recovery based T1 mapping sequences are less sensitive to systematic errors than the Modified Look-Locker Inversion recovery (MOLLI) technique but require high performance saturation pulses. We propose to optimize adiabatic and pulse train saturation pulses for quantitative T1 mapping to have <1 % absolute residual longitudinal magnetization (|MZ/M0|) over ran...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 46  شماره 

صفحات  -

تاریخ انتشار 2017