Quantifying Field-Induced Contrast Effects in Photoelectron Emission Microscopy
نویسندگان
چکیده
Samples consisting of electrically isolated titanium lines fabricated on a titanium surface were used to quantify voltage-induced contrast effects in photoelectron emission microscopy (PEEM). Induced contrast effects were observed to extend 6 μm for a -5 V bias applied to a 303 nm tall raised line. We therefore explored, via numerical calculation, the spatial extent of the perturbation to the PEEM accelerating field caused by the bias applied across the step height. The intensity full width at half minimum agreed well with the calculated width defined by the 10% level of lateral field strength. For a line 550 nm tall, a correspondence was found for a calculated width defined by a 5% lateral field strength. It was observed that neighboring structures a few μm away affected the image contrast, for sufficiently strong applied bias. This suggests that effects can easily be induced at distances of 0.5 μm for modest applied voltages, as has been previously observed for structures buried under oxide layers 0.5 μm thick [1].
منابع مشابه
Plasmonic near-electric field enhancement effects in ultrafast photoelectron emission: correlated spatial and laser polarization microscopy studies of individual Ag nanocubes.
Electron emission from single, supported Ag nanocubes excited with ultrafast laser pulses (λ = 800 nm) is studied via spatial and polarization correlated (i) dark field scattering microscopy (DFM), (ii) scanning photoionization microscopy (SPIM), and (iii) high-resolution transmission electron microscopy (HRTEM). Laser-induced electron emission is found to peak for laser polarization aligned wi...
متن کاملPhotoelectron emission microscopy observation of inversion domain boundaries of GaN-based lateral polarity heterostructures
An intentionally grown GaN film with laterally patterned Gaand N-face polarities is studied using in situ UV-photoelectron emission microscopy ~PEEM!. Before chemical vapor cleaning of the surface, the emission contrast between the Gaand N-face polarities regions was not significant. However, after cleaning the emission contrast between the different polarity regions was enhanced such that the ...
متن کاملModel for doping-induced contrast in photoelectron emission microscopy
We present a model that describes doping-induced contrast in photoelectron emission microscopy by including the effect of surface state distributions and doping-induced band gap reduction. To quantify the contrast, the photoyield from the valence band for near-threshold photoemission is calculated as a function of p-type doping concentration in Si~001!. Various surface state distributions appro...
متن کاملMagnetic dichroisms in absorption and photoemission for magnetic characterization in x-ray photoelectron emission microscopy
Magnetic contrast for the operation of a photoelectron emission microscope ~PEEM! with synchrotron radiation is provided by magnetic dichroisms. Besides the most frequently employed magnetic dichroism, magnetic circular dichroism in x-ray absorption spectroscopy, energy filtering of photoemitted electrons allows one to also use magnetic dichroisms in photoelectron emission as complementary cont...
متن کاملThe Structural and Electron Field Emission Properties of Ion- Beam-Synthesised Metallic-Dielectric Nanocomposites
Metallic-dielectric nanocomposites, including Ag-SiO2, Co-SiO2 and WC-SiC, were synthesised on silicon substrates using ion implantation. The electron field emission (FE) properties of these nanocomposites were studied and correlated to their microstructure determined from the measurements of atomic force microscopy, Rutherford backscattering spectroscopy, x-ray photoelectron spectroscopy and t...
متن کامل