Intravascular sonotherapy decreases neointimal hyperplasia after stent implantation in swine.

نویسندگان

  • P J Fitzgerald
  • A Takagi
  • M P Moore
  • M Hayase
  • F D Kolodgie
  • D Corl
  • M Nassi
  • R Virmani
  • P G Yock
چکیده

BACKGROUND Intimal hyperplasia and subsequent in-stent restenosis remain a major limitation after stent implantation. In vitro cell culture studies show that low-frequency, noncavitational ultrasound energy may impact smooth muscle cell proliferation. Accordingly, we assessed the efficacy of intravascular sonotherapy treatment on intimal hyperplasia in a swine stent model. METHODS AND RESULTS After balloon injury, biliary stents (Johnson & Johnson) were implanted in the femoral arteries of 14 swine. A total of 48 stented sites were randomized to sonotherapy or sham treatment using a custom-built, 8-French catheter intravascular sonotherapy system (URX, PharmaSonics Inc). After stent deployment, ultrasound energy (700 KHz) was applied to the treatment group for up to 5 minutes. Smooth muscle cell proliferation was assessed using bromodeoxyuridine histology preparation (BrdU) at 7 days in 28 stented sites. At 28 days, the neointimal thickness and the ratio of neointimal/stent area (percent stenosis) was calculated by histomorphometric quantification in 20 stented sites. At 7 days, percent of BrdU staining was significantly reduced in the sonotherapy group compared with the sham group (24.1+/-7.0% versus 31.2+/-3.0%, P<0.05). At 28 days, percent stenosis was significantly less in the sonotherapy group than in the sham group (36+/-24% versus 44+/-27%, P<0.05), and the mean neointimal thickness in the sonotherapy group was less than in the sham group (417+/-461 micrometer versus 643+/-869 micrometer, P=0.06). CONCLUSIONS In this swine peripheral model, intravascular sonotherapy seemed to decelerate cellular proliferation and decrease in-stent hyperplasia. Therefore, intravascular sonotherapy may be an effective form of nonionizing energy to reduce in-stent restenosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The pattern of restenosis and vascular remodelling after cold-end radioactive stent implantation.

BACKGROUND Edge restenosis is a major problem after radioactive stenting. The cold-end stent has a radioactive mid-segment (15.9 mm) and non-radioactive proximal and distal 5.7 mm segments. Conceptually this may negate the impact of negative vascular remodelling at the edge of the radiation. METHOD AND RESULTS ECG-gated intravascular ultrasound with three-dimensional reconstruction was perfor...

متن کامل

Persistent inhibition of neointimal hyperplasia after sirolimus-eluting stent implantation: long-term (up to 2 years) clinical, angiographic, and intravascular ultrasound follow-up.

BACKGROUND Early results of sirolimus-eluting stent implantation showed a nearly complete abolition of neointimal hyperplasia. The question remains, however, whether the early promising results will still be evident at long-term follow-up. The objective of our study was to evaluate the efficiency of sirolimus-eluting stent implantation for up to 2 years of follow-up. METHODS AND RESULTS Fifte...

متن کامل

Circulating monocytes and in-stent neointima after coronary stent implantation.

OBJECTIVES The aim of this study was to investigate the relationship between circulating monocytes and in-stent neointimal volume at six-month follow-up. BACKGROUND In-stent neointimal hyperplasia is the main contributing factor to in-stent restenosis. There is increasing evidence that white blood cells (WBCs), especially monocytes, play a central role in restenosis after stent implantation. ...

متن کامل

Radioactive stents delay but do not prevent in-stent neointimal hyperplasia.

BACKGROUND Restenosis after conventional stenting is almost exclusively caused by neointimal hyperplasia. Beta-particle-emitting radioactive stents decrease in-stent neointimal hyperplasia at 6-month follow-up. The purpose of this study was to evaluate the 1-year outcome of (32)P radioactive stents with an initial activity of 6 to 12 microCi using serial quantitative coronary angiography and vo...

متن کامل

Stent design related neointimal tissue proliferation in human coronary arteries; an intravascular ultrasound study.

AIMS Histological restenosis models in animals have indicated that stent design has a significant impact on vessel trauma during stent implantation and on the amount of subsequent neointimal tissue proliferation. The impact of different stent designs on intimal hyperplasia in human atherosclerotic coronary arteries has not been determined. METHODS AND RESULTS Angiographic and intravascular ul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 103 14  شماره 

صفحات  -

تاریخ انتشار 2001