Gating for scanned ion beam therapy

نویسنده

  • Gerhard Kraft
چکیده

In treatment of motion affected tumours by means of a scanned particle beam severe under and over dosage can occur due to the interplay effect. By using gated beam delivery effective target motion is reduced, but even for the residual motion the interplay effect can lead to unsatisfactory dose distributions. Furthermore, an appropriate motion monitoring system is essential since beam delivery has to be synchronized to target motion. In this work three aspects were investigated to move gating closer towards clinical operation at Heidelberg Ion-Beam Therapy Center (HIT): Firstly, influences of beam parameters on dosimetric effects of residual motion were investigated in experiments and simulations. Increased focus sizes and reduced iso-energy distances turned out to be an effective method to gain dose homogeneity whereas reduction of lateral beam position spacing did not show such an effect. Secondly, to enable systematic studies of mitigation techniques and effects of miscorrelation between motion monitoring system and tumour motion a phantom with 6D target and independent thorax motion was constructed and validated successfully in experiments. Thirdly, two motion monitoring systems by VisionRT Ltd. and Anzai Medical Co.,Ltd., respectively, were compared in terms of gating delays and correlation to tumour motion extracted from MV-fluoroscopy. While the VisionRT system showed larger delays than the Anzai system under laboratory conditions, no significant difference between the systems with respect to tumour-correlation was found in a clinical study. Results of this work will be incorporated into patient treatments using gating that will start at HIT within the next few months. Furthermore, a phantom simulating thorax and target motion with a variety of applications such as 4D imaging is now available and already in use by several groups.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Management of organ motion in scanned ion beam therapy

Scanned ion beam therapy has special demands for treatment of intra-fractionally moving tumors such as lesions in lung or liver. Interplay effects between beam and organ motion can in those settings lead to under-dosage of the target volume. Dedicated treatment techniques such as gating or abdominal compression are required. In addition 4D treatment planning should be used to determine strategi...

متن کامل

4D treatment planning for scanned ion beams

At Gesellschaft für Schwerionenforschung (GSI) more than 330 patients have been treated with scanned carbon ion beams in a pilot project. To date, only stationary tumors have been treated. In the presence of motion, scanned ion beam therapy is not yet possible because of interplay effects between scanned beam and target motion which can cause severe mis-dosage. We have started a project to trea...

متن کامل

Treatment planning study: Motion mitigation techniques for lung tumors

Introduction Currently, the C-12 therapy performed at GSI cannot be applied to moving tumors because interplay between scanned ion beam and moving target does not allow controlled dose delivery. Several techniques are proposed to mitigate the influence of interplay. Among them are tracking [1], gating [2], rescanning [3], and use of margins. We used the 4D extension of GSI’s treatment planning ...

متن کامل

Multigating, a 4D Optimized Beam Tracking in Scanned Ion Beam Therapy

The treatment of moving tumors with a scanned ion beam is challenging due to interplay effects and changing beam range. We propose multigating, as a method for 4D-treatment optimization and delivery. In 3D beam tracking, tracking vectors are added during delivery to beam spot positions based on the detected motion phase. This has the disadvantage of dose errors in case of complex motion pattern...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011