An electrical artifact associated with the ERG-jet gold foil electrode.

نویسندگان

  • P L Gehlbach
  • R L Purple
چکیده

PURPOSE To examine a photoelectric artifact associated with the ERG-jet corneal contact lens electrode (Universe SA, La Chaux-de-Fons, Switzerland). METHODS An artifact associated with the ERG-jet, gold foil corneal contact lens electrode was reproduced in vitro and in vivo using 50 msec light flashes. In vitro responses were examined using light flashes that varied in intensity, duration, and wavelength. Ionic strength of the bathing solution and temperature dependence were also examined. In vivo responses were compared to similarly recorded signals using the Burian-Allen bipolar electrode. RESULTS The artifact is not apparent with microsecond light flashes, as with the Grass PS22 Photo-stimulator connected to a Ganzfeld. Longer light flashes and increasing light intensities, however, elicit graded responses that may resemble the late PIII component of the ERG in profile and in magnitude. The artifact varies with temperature, ionic concentration of the bathing medium, and wavelength of stimulating light. The artifact also varies in magnitude and polarity from one disposable electrode to the next. Light flashes of shorter wavelengths elicit greater responses than light flashes of equal radiant energy but of longer wavelengths. CONCLUSIONS The artifact derives from electrode polarization occurring at the interface between the gold foil and its ionic medium. Caution is required when using light stimuli longer than 2-3 msec with this and similar types of intrinsically polarizable metal electrodes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of repeat use and coating defects of gold foil electrodes on electroretinogram recording

Qualitative defects and resistances in 94 used gold foil electrodes were examined. The electrodes were divided into four groups of varying resistances and gold coating defects. Ten were randomly selected from each group to measure standard photopic electroretinograms (ERGs) in a normal subject. Ten new electrodes were used as controls. There was no significant difference among the electrode gro...

متن کامل

A gold foil electrode: extending the horizons for clinical electroretinography.

A gold foil ERG electrode is described. The device is inexpensive and simple to fabricate. Since it is hooked over the lower lid and makes minimal touch contact with the inferior limbal area, it can be used in circumstances which require prolonged testing of retinal function or in eyes with corneal pathology. Because the optics of the eye are not compromised, it is possible, with the use of app...

متن کامل

Determination of the flux of a neutron radioisotope source through gold activation method

Introduction: In recent years, the use of neutrons has increased in various fields such as medicine and industry. One of the important applications of neutrons is in medical research. Neutrons have greater linear energy transfer than gamma rays and are considered more dangerous radiation. Hence, the detection and determination of neutron dose is a very important and vital issu...

متن کامل

Electroretinography in dogs using a fiber electrode prototype

We compared two electroretinography (ERG) electrodes in dogs using ERG standards of the International Society for Clinical Electrophysiology of Vision (ISCEV). Ten healthy Yorkshire terrier dogs (mean age, 2.80 ± 1.42 years; 6 females) weighing 5.20 ± 1.56 kg were evaluated using an ERG system for veterinary use. Dark- and light-adapted ERG responses were recorded using an ERG-Jet electrode and...

متن کامل

Simulation and Modeling of a High Sensitivity Micro-electro-mechanical Systems Capacitive Pressure Sensor with Small Size and Clamped Square Diaphragm

This paper proposes a Micro-electro-mechanical (MEMS) capacitive pressure sensor that relies on the movable electrode displaced like a flat plate equal to the maximum center deflection of diaphragm. The diaphragm, movable electrode and mechanical coupling are made of polysilicon, gold and Si3N4, respectively. The fixed electrode is gold and the substrate is Pyrex glass. This proposed method inc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 34 8  شماره 

صفحات  -

تاریخ انتشار 1993