Integrated microscopy techniques for comprehensive pathology evaluation of an implantable left atrial pressure sensor
نویسندگان
چکیده
The safety and efficacy of an implantable left atrial pressure (LAP) monitoring system is being evaluated in a clinical trial setting. Because the number of available specimens from the clinical trial for histopathology analysis is limited, it is beneficial to maximize the usage of each available specimen by relying on integrated microscopy techniques. The aim of this study is to demonstrate how a comprehensive pathology analysis of a single specimen may be reliably achieved using integrated microscopy techniques. Integrated microscopy techniques consisting of high-resolution gross digital photography followed by micro-computed tomography (micro-CT) scanning, low-vacuum scanning electron microscopy (LVSEM), and microground histology with special stains were applied to the same specimen. Integrated microscopy techniques were applied to eight human specimens. Micro-CT evaluation was beneficial for pinpointing the location and position of the device within the tissue, and for identifying any areas of interest or structural flaws that required additional examination. Usage of LVSEM was reliable in analyzing surface topography and cell type without destroying the integrity of the specimen. Following LVSEM, the specimen remained suitable for embedding in plastic and sectioning for light microscopy, using the positional data gathered from the micro-CT to intersect areas of interest in the slide. Finally, hematoxylin and eosin (H&E) and methylene blue staining was deployed on the slides with high-resolution results. The integration of multiple techniques on a single specimen maximized the usage of the limited number of available specimens from the clinical trial setting. Additionally, this integrated microscopic evaluation approach was found to have the added benefit of providing greater assurance of the derived conclusions because it was possible to cross-validate the results from multiple tests on the same specimen.
منابع مشابه
An Implantable Left Atrial Pressure Sensor Lead Designed for Percutaneous Extraction Using Standard Techniques
BACKGROUND An implantable left atrial pressure (LAP) monitoring system for guiding the management of patients with advanced heart failure has the potential to require extraction, particularly in the setting of infection. The LAP sensor lead was designed to be suitable for ease of percutaneous extraction using standard techniques for extracting pacemaker and defibrillator leads. The clinical exp...
متن کاملLeft Atrial Pressure Monitoring With an Implantable Wireless Pressure Sensor After Implantation of a Left Ventricular Assist Device
After implantation of a continuous-flow left ventricular assist device (LVAD), left atrial pressure (LAP) monitoring allows for the precise management of intravascular volume, inotropic therapy, and pump speed. In this case series of 4 LVAD recipients, we report the first clinical use of this wireless pressure sensor for the long-term monitoring of LAP during LVAD support. A wireless microelect...
متن کاملA Semi-Automated Algorithm for Segmentation of the Left Atrial Appendage Landing Zone: Application in Left Atrial Appendage Occlusion Procedures
Background: Mechanical occlusion of the Left atrial appendage (LAA) using a purpose-built device has emerged as an effective prophylactic treatment in patients with atrial fibrillation at risk of stroke and a contraindication for anticoagulation. A crucial step in procedural planning is the choice of the device size. This is currently based on the manual analysis of the “Device Landing Zone” fr...
متن کاملIntegrated Percutaneous Atrial Septal Defect Occlusion and Pulmonary Balloon Valvuloplasty
Introduction: Atrial Septal Defect (ASD) is one of the most common congenital heart diseases during childhood. Today, ASD closure is done by occlutech device via cardiac catheterization. ASD repair with transcatheter technique has shown high closure rate. However, coexistence of severe pulmonary stenosis and large defect in atrial septum is rare. When these two problems coexist, the result is i...
متن کاملA New Comprehensive Sensor Network Design Methodology for Complex Nonlinear Process Plants
This paper presents an optimal integrated instrumentation sensor network design methodology for complex nonlinear chemical process plants using a Combinatorial Particle Swarm Optimiazation (CPSO) engine. No comprehensive sensor network design approach has been addressed yet in the literature to simultaneously incorporate cost, precision and reliability requirements for nonlinear plant...
متن کامل