Is the axilla the right site for temperature measurement in children by chemical thermometer?

نویسندگان

  • Ateş Kara
  • Ilker Devrim
  • Ali Bülent Cengiz
  • Filiz Celik
  • Hasan Tezer
  • Ali Kerem Uludağ
  • Gülten Seçmeer
چکیده

Although each method has its own advantages and disadvantages compared with the conservative mercury-in-glass thermometers, there are conflicting opinions about the optimal anatomic site for measuring body temperature as well about the variations in measurements with different methods. In this study, we aimed to assess the accuracy and reliability of measurements obtained from the axilla with the chemical thermometer (Tempa DOT TM) compared with the classic mercury-in-glass instruments. Sixty randomly selected pediatric patients who were admitted to our hospital were enrolled. Simultaneous temperature axillary measurements (n: 1300) were performed with the chemical thermometer and mercury-in-glass instruments. The mean results of the axillary mercury-in-glass thermometers and axillary chemical thermometer were 36.8 +/- 0.6 and 37.2 +/- 0.7, respectively. The Bland-Altman plot of differences suggests that 95% of the chemical thermometer (Tempa.DOT TM) readings were within limits of agreement (+0.37 and -1.24 degrees C) when mercury-in-glass thermometer is considered as the standard. Our results showed that limits of agreement were wide (+0.37 and -1.24 degrees C) between readings of axillary mercury-in-glass thermometers and chemical thermometers. Since approximately 20% of febrile patients with mercury-in-glass temperature were misdiagnosed as afebrile with measurements via chemical thermometer, we suggest that the axilla is not a suitable anatomic site for screening of fever with Tempa.DOT. Further studies involving larger study groups with similar age should be done to more definitely assess its screening value in pediatrics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Temperature measured at the axilla compared with rectum in children and young people: systematic review.

OBJECTIVE To evaluate the agreement between temperature measured at the axilla and rectum in children and young people. DESIGN A systematic review of studies comparing temperature measured at the axilla (test site) with temperature measured at the rectum (reference site) using the same type of measuring device at both sites in each patient. Devices were mercury or electronic thermometers or i...

متن کامل

An evaluation of tympanic thermometry in a paediatric emergency department.

BACKGROUND AND OBJECTIVES The consequences of missing fever in children can be grave. Body temperature is commonly recorded at the axilla but accuracy is a problem. This study aimed to evaluate the accuracy of a tympanic thermometer in the paediatric emergency setting. METHOD In a total of 106 infants, the body temperature was measured in the daytime with an infrared tympanic thermometer, and...

متن کامل

Comparison sensitivity and specificity temporal artery temperature measurement with axillary and nasopharyngeal methods in adult

      Aims: temporal artery thermometers (TAT) of new tools for measuring body temperature, few studies have been conducted to evaluate the accuracy and reliability of thermometers and is still uncertain accuracy and reliability this thermometers.This study to evaluate the accuracy of the two methods of measuring body temperature by the thermometer axillary and temporal artery compared with nas...

متن کامل

Tympanic membrane temperature as a measure of core temperature.

BACKGROUND Ear thermometers are becoming popular as a method for measuring deep body (core) temperature. AIM To determine the variability of a single user's tympanic membrane (ear) temperature measurements. SUBJECTS Forty-two, afebrile, healthy children, and 20 febrile children with acute burns. RESULTS In afebrile children measurements made in both ears (and within just a few minutes of ...

متن کامل

مقایسه دمای اندازه گیری شده بدن به وسیله ترمومتر جیوه ای و دیجیتالی

  Background and Aim: Mercury is a dangerous substance for human health and mercury thermometers are major pollutant for environment. Using less dangerous and less expensive devices like digital thermometer can be an alternative for mercury thermometers. The aim of this study was to compare the body temperature measurement by mercury and digital thermometer.   Material and Method : In this desc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Turkish journal of pediatrics

دوره 51 4  شماره 

صفحات  -

تاریخ انتشار 2009