Transesophageal echocardiographic guidance for percutaneous closure of aortic pseudoaneurysm using a type II Amplatzer vascular plug: a case report

نویسندگان

  • Hyo Jin Kim
  • Sangmin Maria Lee
  • Kiick Sung
  • I-Seok Kang
  • Jong-Hwan Lee
  • Jeong Jin Min
  • Eunhee Kim
  • Jiyeon Park
  • Jin Hyoung Park
چکیده

Aortic pseudoaneurysm after cardiac surgery is a rare entity, but it is potentially fatal due to its clinical course along with higher morbidity and mortality rates. Instead of open surgical repair, percutaneous procedures have been introduced as other options for managing an aortic pseudoaneurysm. In this case report, we describe transesophageal echocardiography guidance for successful percutaneous closure of an aortic pseudoaneurysm located in the left ventricular outflow tract by using a type II Amplatzer vascular plug in a patient in whom open surgical repair was not recommended.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Paravalvular leak closure with the Amplatzer Vascular Plug III device: immediate and short-term results.

INTRODUCTION AND OBJECTIVES Percutaneous paravalvular leak closure is a complex procedure with varying success rates; the lack of closure devices specifically designed for this purpose has hampered this technique. The characteristics of the Amplatzer Vascular Plug III appear to be well suited for paravalvular leak closures; however, the available data are limited to case reports or small series...

متن کامل

Transcatheter aortic paravalvular leak closure using 3 Amplatzer Vascular Plug III devices in a child

Paravalvular leak (PVL) is usually related to disruption of prosthetic valve sewing ring sutures. Many previous reports have described transcatheter paravalvular leak closure in adult patients [1–4], but those describing such a procedure in children are scarce. A 16-year-old boy underwent an aortic valve replacement (AVR) with a stented bioprosthesis Hancock 23 mm due to combined aortic stenosi...

متن کامل

Use of the amplatzer vascular plug II device to occlude different types of patent ductus arteriosus in pediatric patients.

INTRODUCTION Transcatheter patent ductus arteriosus (PDA) closure is difficult in small patients in part due to the diverse PDA morphology. We describe a multicenter pediatric experience using the Amplatzer Vascular Plug II device (AVP II) to occlude PDA. METHODS All patients undergoing transcatheter closure of PDA with AVP II from April 2008 until May 2012 were included. Clinical, angiograph...

متن کامل

Clinical manifestations of heart failure abate with transcatheter aortic paravalvular leak closure using Amplatzer vascular plug II and III devices.

OBJECTIVES To evaluate the transcatheter paravalvular leak closure (TPVLC) aptitude to reduce manifestations of heart failure caused by aortic paravalvular leak (PVL). BACKGROUND TPVLC is a valuable alternative to reoperation. While technical feasibility of the method is well established, data on long-term clinical outcome are less abundant. METHODS We launched a prospective registry of pat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 69  شماره 

صفحات  -

تاریخ انتشار 2016