Comparison of the frictional characteristics of aesthetic orthodontic brackets measured using a modified in vitro technique
نویسندگان
چکیده
OBJECTIVE The coefficients of friction (COFs) of aesthetic ceramic and stainless steel brackets used in conjunction with stainless steel archwires were investigated using a modified linear tribometer and special computer software, and the effects of the bracket slot size (0.018 inches [in] or 0.022 in) and materials (ceramic or metal) on the COF were determined. METHODS Four types of ceramic (one with a stainless steel slot) and one conventional stainless steel bracket were tested with two types of archwire sizes: a 0.017 × 0.025-in wire in the 0.018-in slots and a 0.019 × 0.025-in wire in the 0.022-in slot brackets. For pairwise comparisons between the 0.018-in and 0.022-in slot sizes in the same bracket, an independent sample t-test was used. One-way and two-way analysis of variance (ANOVA) and Tukey's post-hoc test at the 95% confidence level (α = 0.05) were also used for statistical analyses. RESULTS There were significant differences between the 0.022-in and 0.018-in slot sizes for the same brand of bracket. ANOVA also showed that both slot size and bracket slot material had significant effects on COF values (p < 0.001). The ceramic bracket with a 0.022-in stainless steel slot showed the lowest mean COF (µ = 0.18), followed by the conventional stainless steel bracket with a 0.022-in slot (µ = 0.21). The monocrystalline alumina ceramic bracket with a 0.018-in slot had the highest COF (µ = 0.85). CONCLUSIONS Brackets with stainless steel slots exhibit lower COFs than ceramic slot brackets. All brackets show lower COFs as the slot size increases.
منابع مشابه
Evaluation of the Effect of an Experimental Herbal versus Fluoridated Mouthwash on Frictional Resistance and Surface Roughness between Orthodontic Brackets and Two Types of Archwire: In Vitro Study
Introduction: The present study aimed to evaluate an experimental herbal mouthwash, as compared to sodium fluoride mouthwash on the frictional resistance and surface roughness between brackets and two rectangular archwire types. Methods: A total of 60 premolar׳s brackets engaged with 0.019×0.025 archwires made of stainless steel and nickel-titanium alloys were used in this study. The samples we...
متن کاملIn-Vitro Evaluation of Frictional Resistance of three Different Aesthetic Self Ligating Brackets Using two Archwire Alloys
Aim: To estimate and compare the frictional forces engendered by three types of aestheticselfligating brackets with two straight wire alloys. Materials: The study comprised of a total of 90 brackets, of which 30 passive (Damon clear 2),30 active(GAC In-Ovation C) and 30 interactive (Empower clear) orthodontic brackets with a slot size of .022X.028 MBT prescription in combination with stainless ...
متن کاملA comparative in vitro study of frictional resistance between lingual brackets and stainless steel archwires.
Friction between archwires and labial brackets has received considerable attention; however, information on the frictional behaviour of commercially available lingual brackets is limited. The aim of this study was to investigate the frictional resistance resulting from a combination of lingual orthodontic brackets (7th Generation, STb, Magic, and In-Ovation L) and stainless steel archwires at 0...
متن کاملComparison of static friction with self-ligating, modified slot design and conventional brackets
OBJECTIVE To compare the static frictional forces generated at the bracket/wire interface of stainless steel brackets with different geometries and angulations, combined with orthodontic wires of different diameters. MATERIAL AND METHODS The frictional forces were evaluated with three different types of metal brackets: a passive self-ligating (SmartClipTM, 3M/Unitek, Monrovia, USA), with a mo...
متن کاملبررسی مقاومت اصطکاکی سیم نیکل تیتانیوم ارتودنسی در زوایای مختلف قرارگیری براکت و سیم
Background and Objective: Resistance to sliding is a combination of friction and binding. When the angle between the bracket and the wire exceeds the critical angle, binding occurs. The influence of angulation is confounding because of certain inherent physical characteristics of materials. The present study was carried out to evaluate the effect of wire- bracket angulation on resistance to sli...
متن کامل