Interrater and test-retest reliability and validity of the Norwegian version of the BESTest and mini-BESTest in people with increased risk of falling
نویسندگان
چکیده
BACKGROUND The Balance Evaluation Systems Test (BESTest) was developed to assess underlying systems for balance control in order to be able to individually tailor rehabilitation interventions to people with balance disorders. A short form, the Mini-BESTest, was developed as a screening test. The study aimed to assess interrater and test-retest reliability of the Norwegian version of the BESTest and the Mini-BESTest in community-dwelling people with increased risk of falling and to assess concurrent validity with the Fall Efficacy Scale-International (FES-I), and it was an observational study with a cross-sectional design. METHODS Forty-two persons with increased risk of falling (elderly over 65 years of age, persons with a history of stroke or Multiple Sclerosis) were assessed twice by two raters. Relative reliability was analysed with Intraclass Correlation Coefficient (ICC), and absolute reliability with standard error of measurement (SEM) and smallest detectable change (SDC). Concurrent validity was assessed against the FES-I using Spearman's rho. RESULTS The BESTest showed very good interrater reliability (ICC = 0.98, SEM = 1.79, SDC95 = 5.0) and test-retest reliability (rater A/rater B = ICC = 0.89/0.89, SEM = 3.9/4.3, SDC95 = 10.8/11.8). The Mini-BESTest also showed very good interrater reliability (ICC = 0.95, SEM = 1.19, SDC95 = 3.3) and test-retest reliability (rater A/rater B = ICC = 0.85/0.84, SEM = 1.8/1.9, SDC95 = 4.9/5.2). The correlations were moderate between the FES-I and both the BESTest and the Mini-BESTest (Spearman's rho -0.51 and-0.50, p < 0.01). CONCLUSION The BESTest and its short form, the Mini-BESTest, showed very good interrater and test-retest reliability when assessed in a heterogeneous sample of people with increased risk of falling. The concurrent validity measured against the FES-I showed moderate correlation. The results are comparable with earlier studies and indicate that the Norwegian versions can be used in daily clinic and in research.
منابع مشابه
Is the BESTest at its best? A suggested brief version based on interrater reliability, validity, internal consistency, and theoretical construct.
BACKGROUND The Balance Evaluation Systems Test (BESTest) and Mini-BESTest are clinical examinations of balance impairment, but the tests are lengthy and the Mini-BESTest is theoretically inconsistent with the BESTest. OBJECTIVE The purpose of this study was to generate an alternative version of the BESTest that is valid, reliable, time efficient, and founded upon the same theoretical underpin...
متن کاملبررسی روایی و پایایی آزمون ارزیابی سیستمهای تعادلی (آزمون بس) در ارزیابی اختلالات تعادلی بیماران مبتلا به مولتیپلاسکلروزیس
Objective Balance system and postural control are one of the major problems in people with multiple sclerosis. Therefore, the assessment of the balance system and postural control is very essential. Identification and use of standard tools can be a practical solution for more purposeful plan in this issue. Several tools have been used to investigate the balance disorders in these patients, whic...
متن کاملReliability of the Balance Evaluation Systems Test (BESTest) and BESTest sections for adults with hemiparesis
BACKGROUND The Balance Evaluation Systems Test (BESTest) was recently created to allow the development of treatments according to the specific balance system affected in each patient. The Brazilian version of the BESTest has not been specifically tested after stroke. OBJECTIVE To evaluate the intra- and inter-rater reliability and concurrent and convergent validity of the total score of the B...
متن کاملFunctional gait assessment and balance evaluation system test: reliability, validity, sensitivity, and specificity for identifying individuals with Parkinson disease who fall.
BACKGROUND Gait impairments, balance impairments, and falls are prevalent in individuals with Parkinson disease (PD). Although the Berg Balance Scale (BBS) can be considered the reference standard for the determination of fall risk, it has a noted ceiling effect. Development of ceiling-free measures that can assess balance and are good at discriminating "fallers" from "nonfallers" is needed. ...
متن کاملThe Mini-BESTest - a clinically reproducible tool for balance evaluations in mild to moderate Parkinson’s disease?
BACKGROUND The Mini-BESTest is a clinical balance test that has shown a high sensitivity in detecting balance impairments in elderly with Parkinson's disease (PD). However, its reproducibility between different raters and between test occasions has yet to be investigated in a clinical context. Moreover, no one has investigated the reproducibility of the Mini-BESTest's subcomponents (i.e. antici...
متن کامل