Evaluation of coronary allograft vasculopathy using multi-detector row computed tomography: a systematic review.
نویسندگان
چکیده
Coronary allograft vasculopathy (CAV) is a significant cause of morbidity and mortality after cardiac transplantation and requires frequent surveillance with catheter-based coronary angiography (CCA). Multi-detector row computed tomography (MDCT) has been shown to be effective in assessing atherosclerosis in native coronary arteries. This article systematically reviews the literature to determine the accuracy of MDCT in CAV assessment. An English-language literature search was performed using EMBASE, OVID, PubMed, and Cochrane Library databases. Studies that directly compared MDCT with CCA and/or IVUS for the detection of coronary artery stenosis or significant intimal thickening in cardiac transplant patients were analyzed. Data were pooled to obtain weighted sensitivities, specificities, and diagnostic accuracies. Negative and positive predictive values (NPV/PPV) were calculated. A total of seven studies with a sum of 272 patients were included in this review. There were three studies examining 16-slice MDCT and four studies looking at 64-slice MDCT in CAV. Using per-segment analysis, MDCT assessed between 91% and 96% of all coronary segments when evaluating for stenosis. Pooled estimates for sensitivity and specificity for MDCT ranged from 82% to 89% and 89% to 99%, respectively, while NPV was 99%. Per-patient analysis revealed a sensitivity of 87-100% and NPV of 96-100%. PPV was less than 50% for 64-slice MDCT in both per-segment and per-patient analysis. When compared with IVUS, MDCT had a sensitivity of 74-96% and specificity of 88-92% in assessment of intimal thickening. NPV and PPV were 80-81% and 84-98%, respectively. The high sensitivity and NPV of MDCT suggest that it may be a useful, noninvasive screening tool to rule out CAV.
منابع مشابه
The challenge to detect heart transplant rejection and transplant vasculopathy non-invasively - a pilot study
BACKGROUND Cardiac allograft rejection and vasculopathy are the main factors limiting long-term survival after heart transplantation.In this pilot study we investigated whether non-invasive methods are beneficial to detect cardiac allograft rejection (Grade 03 R) and cardiac allograft vasculopathy. Thus we compared multi-slice computed tomography and magnetic resonance imaging with invasive met...
متن کاملPitfalls, artifacts, and remedies in multi- detector row CT coronary angiography.
Coronary angiography is increasingly performed with multi-detector row computed tomography (CT) in the clinical setting. Successful use of this method, however, depends on the radiologist's knowledge of its potential pitfalls and familiarity with methods for minimizing or avoiding them. To identify artifacts and other pitfalls that commonly degrade image quality and that could result in misinte...
متن کاملProtective effects of pomegranate seed oil on ovariectomized rats as a model of postmenopausal osteoporosis: A multi-detector computed tomography evaluation
The pomegranate seed oil (PSO), containing 17-α-estradiol, is one of the newly found phytosterols with synergistic health effects on estrogen related physiological conditions. Herein, PSO was assessed for its potential improving effects on bone characteristics in a rat model of menopausal syndrome. Three month old non-pregnant female Wistar rats (n = 30) were either sham-operated (SHAM) or ovar...
متن کاملNon-invasive imaging of sutureless vein graft anastomosis with 16-slice multi-detector row spiral computed tomography.
Contrast-enhanced 16-slice multi-detector row spiral computed tomography (MDCT) has been shown to be useful for non-invasive visualization of aortocoronary bypass grafts (CABG). This new-generation scanner could be a good alternative to the common invasive coronary angiography. In this article, we report a patient operated on with the St. Jude Medical, Inc, Symmetry Bypass System (Aortic Connec...
متن کاملCoronary artery aneurysm with thrombus evaluated by multi-detector row computed tomography.
This is a case report of a 60-year-old woman with acute myocardial infarction (AMI) who had coronary aneurysms and thrombus in the right coronary artery detected by multi-detector row computed tomography (MDCT). In this case, MDCT was useful for clarifying the thrombus complicated with coronary aneurysms, which was considered to be the cause of AMI. Thus, warfarin was started as an anticoagulan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 41 2 شماره
صفحات -
تاریخ انتشار 2012