Mandibular erosion from silastic implants: evaluation with a dental CT software program.

نویسندگان

  • J J Abrahams
  • C Caceres
چکیده

Silastic implants used to augment the chin during cosmetic surgery may cause erosive bone changes and complications. We describe the radiologic appearance of these changes and the dental CT reformatting programs by which they may be assessed. Multiplanar CT scans of four patients with Silastic chin implants were evaluated retrospectively for implant density, presence and size of bone defects, relationship of defects to root apices, relationship of defects to mental foramen, and associated findings. The dental CT software program was instrumental in delineating the relationship between the bone defects and the root apices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CT in the preoperative assessment of the mandible and maxilla for endosseous implant surgery. Work in progress.

A new computer software program that generates panoramic and oblique computed tomography scans was used to examine 205 patients who were being considered for endosseous dental implants in the mandibular or maxillary arches. This technique allowed recognition of the course of the inferior alveolar nerve canal and measurement of the alveolar ridge, which facilitated the design and placement of an...

متن کامل

Odontogenic cysts: improved imaging with a dental CT software program.

PURPOSE To evaluate a dental CT software program to determine whether it can provide a better means of assessing odontogenic cysts, lesions of the jaw derived from dental epithelium, than conventional techniques (orthopantomographic, intraoral, and mandibular films), which are of limited usefulness because of the curved configuration of the mandible; and to provide a brief review of these lesio...

متن کامل

Mandibular Dimensional Changes with aging in Three Dimensional Computed Tomographic Study in 21 to 50 Year old Men and Women

Introduction: Raising the knowledge of skeletal and soft tissue changes with aging has been highly essential due to an increasing demand for aesthetic facial surgery following aging. The aim of this study is to evaluate the three dimensional computed tomographic images and process of changes in mandible with aging. Materials and Methods: In this descriptive study, the facial CT scans were obta...

متن کامل

تعیین توزیع تنش استخوان اطراف ایمپلنت‌های فک پایین در طرح‎های مختلف پروتز به هنگام Mandibular- Flexure

Statement of Problem: In the treatment of edentulous patients with implant supported fixed partial dentures several factors such as implant numbers, implant position, superstructure pattern and cantilever length must be considered. Mandibular flexture in function exerts forces in peri-implant bone, however this phenomenon has received little attention. Purpose: The goal of this finite element a...

متن کامل

The use of a computerized tomography-based software program with a flapless surgical technique in implant dentistry: a case report.

Successful implant treatment includes osseointegration, as well as prosthetically optimal positions of the implants for esthetics and function. The aim of this study is to evaluate a patient that was treated with an implant-supported fixed prosthesis with the help of computer-assisted three-dimensional planning. A 52-year-old edentulous man underwent computerized tomographic (CT) scanning, and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 19 3  شماره 

صفحات  -

تاریخ انتشار 1998