Retrogated spiral 3-directional myocardial phase velocity mapping in a single breath-hold
نویسندگان
چکیده
Background Myocardial phase velocity mapping studies have generally been acquired using Cartesian k-space coverage and respiratory gating [1,2]. Acquisition durations for high temporal resolution studies are therefore long and unpredictable and the use of navigators and prospective cardiac gating results in ‘dead-times’ in the cardiac cycle where imaging cannot be performed. We have developed a technique which combines highly efficient spiral k-space coverage with retrospective cardiac gating for 3D velocity mapping over the entire cardiac cycle within a breath-hold. The feasibility for rapid assessment of myocardial motion is demonstrated.
منابع مشابه
Navigator gated high temporal resolution tissue phase mapping of myocardial motion.
Data acquisition for phase contrast velocity mapping of myocardial motion is typically based on multiple breath-held 2D measurements with limited acquisition duration and consequently relatively poor temporal resolution. In order to overcome the limitations of breath-hold acquisitions, an improved navigator-guided technique was implemented based on 2 navigator signals within each cardiac cycle ...
متن کاملInter-study reproducibility of interleaved spiral phase velocity mapping of renal artery haemodynamics
BACKGROUND Qualitative and quantitative assessment of renal blood flow is valuable in the evaluation of patients with renal and renovascular diseases as well as in patients with heart failure. The temporal pattern of renal flow velocity through the cardiac cycle provides important information about renal haemodynamics. High temporal resolution interleaved spiral phase velocity mapping could pot...
متن کاملValidation of high temporal resolution spiral phase velocity mapping of coronary artery blood flow against Doppler flow wire
Background The temporal pattern of coronary artery flow velocity through the cardiac cycle provides important information about coronary haemodynamics. The ‘gold standard’ for coronary artery velocity assessment is the Doppler flow wire which is inserted directly into the coronary artery under X-ray fluoroscopic guidance, which is invasive, uses ionising radiation and has a small but significan...
متن کاملLate Gadolinium Enhancemnet imaging of the Left Ventricle in a single breath-hold using multi-slice spiral PSIR imaging at 3T
Background Late gadolinium enhancement (LGE) imaging is the standard method of assessment of myocardial viability. Conventional Cartesian phase sensitive inversion recovery (PSIR) LGE imaging is usually performed as a stack of 2D slices, with each slice being acquired in a single breath-hold [1]. Repeated breath-holding is time consuming and can be difficult or tiring for patients which can lea...
متن کاملFast Velocity Mapping of Myocardial Motion with k-Space Segmented Black Blood Echo Planar and Gradient Echo Imaging
Introduction: Cine or multi-phase cardiac imaging offers a variety of applications such as assessment of global cardiac function, measurement of the heart wall motion with phase contrast [1] or tagging techniques [2] as well as determination of flow inside the ventricular system. Here, we present two fast imaging methods for assessment of myocardial motion: Interleaved Echo Planar Imaging (EPI)...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 14 شماره
صفحات -
تاریخ انتشار 2012