Procedural results and intermediate clinical outcomes after multiple saphenous vein graft stenting.

نویسندگان

  • B Bhargava
  • R Kornowski
  • R Mehran
  • K M Kent
  • M K Hong
  • A J Lansky
  • R Waksman
  • A D Pichard
  • L F Satler
  • M B Leon
چکیده

OBJECTIVES We evaluated the early and mid-term (18-month) clinical events in a consecutive series of patients undergoing a nonstaged multiple saphenous vein grafting (SVG) intervention with stents as compared with a single SVG stent procedure. BACKGROUND Saphenous vein graft angioplasty has been limited by high rates of distal embolization, myocardial infarction, restenosis and late mortality. It is unknown whether stenting of multiple, different SVGs at the same setting is associated with higher risk. METHODS We evaluated in-hospital and mid-term clinical outcomes (death, Q wave myocardial infarction [MI] and repeat revascularization rates up to 18 months) in 70 consecutive patients treated with coronary stents in 2 (93% of patients) or 3 SVGs, as compared with 649 patients undergoing stenting of a single SVG between January 1, 1994 and December 31, 1997. RESULTS Overall procedural success was obtained in 97% of patients with 2 or 3 SVGs and 97% of patients with a single SVG (p = 0.94). Procedural complications were also similar (2.8% for multiple SVGs vs. 2.7% for a single SVG, p = 0.94). There was a higher prevalence of periprocedural non-Q wave MI (28% vs. 16%, p = 0.009) in the multiple SVG group. During follow-up (18 months), target lesion revascularization was 11% in multiple SVG and 15% in single SVG interventions (p = 0.19), and repeat revascularization (calculated per treated patient) was also similar for both groups (19% vs. 18%, p = 0.94). There was no difference in death (5.6% vs. 5.3%, p = 0.92) and Q wave MI rate (4.3% vs. 2.9%, p = 0.55) after the multiple SVG intervention. Overall cardiac event-free survival was similar for both groups (62% vs. 60%, p = 0.75). The study was powered to detect a clinically meaningful difference of 10% in mortality; smaller differences could not be evaluated on the basis of this sample size. CONCLUSIONS Simultaneous stenting of multiple SVGs in carefully selected patients has similar in-hospital procedural success and major complications rates, as well as mid-term (18-month) clinical outcomes, as compared with single SVG stenting. Thus, multiple SVG interventions using stents may be a viable revascularization strategy for carefully selected patients and suitable lesions in multiple SVG disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continued benefit from paclitaxel-eluting compared with bare-metal stent implantation in saphenous vein graft lesions during long-term follow-up of the SOS (Stenting of Saphenous Vein Grafts) trial.

OBJECTIVES This study sought to report the long-term outcomes after drug-eluting stent (DES) implantation in saphenous vein graft (SVG) lesions in the SOS (Stenting of Saphenous Vein Grafts) trial. BACKGROUND The long-term outcomes after DES implantation in SVGs are poorly studied. Apart from the SOS trial, the only other randomized trial comparing DES with bare-metal stents (BMS) in SVGs rep...

متن کامل

Comparison of debulking followed by stenting versus stenting alone for saphenous vein graft aortoostial lesions: immediate and one-year clinical outcomes.

OBJECTIVES We compared in-hospital and one-year clinical outcomes in patients undergoing debulking followed by stent implantation versus stenting alone for saphenous vein graft (SVG) aortoostial lesions. BACKGROUND Stent implantation in SVG aortoostial lesions may improve procedural and late clinical outcomes. However, the impact of debulking before stenting in this complex lesion subset is u...

متن کامل

Long-term outcomes of saphenous vein graft stenting compared with native coronary artery stenting in patients with previous coronary artery bypass graft surgery.

OBJECTIVE Our main objective was to compare the in-hospital and long-term outcomes of saphenous vein graft stenting and native coronary artery stenting in patients with previous coronary artery bypass grafting. METHODS We studied 127 patients who had prior coronary artery bypass; they were divided in two groups, according to the kind of percutaneous coronary intervention performed. The first ...

متن کامل

Procedural results and distal embolization after saphenous vein graft stenting and angioplasty for in-stent restenosis of grafts.

Saphenous vein graft (SVG) angioplasty is associated with frequent periprocedural complications due to distal embolization and a high risk of restenosis. The purpose of this single-center, retrospective study was to determine the distal embolization incidences and outcomes of stenting for SVG lesions and percutaneous angioplasty for in-stent restenosis of these SVGs. We studied 48 consecutive p...

متن کامل

Et tu, bare metal stent?

When performing percutaneous coronary revascularization, physicians nearly always supplement balloon angioplasty with a stent.1 This decision is based on evidence that stent implantation enhances the procedural success and durability of angioplasty. Benefits of stenting, compared with balloon angioplasty, include a reduction in the incidence of lesion recurrence, manifested as reduced need for ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 35 2  شماره 

صفحات  -

تاریخ انتشار 2000