Capillary versus Venous Blood Glucose in Patients with Coma

نویسنده

  • Viroj Wiwanitkit
چکیده

1 Dear Sir, The recent publication on “comparison of capillary and venous blood glucose levels using glucometer and laboratory blood glucose level in poisoned patients being in coma” is very interesting.[1] Yaraghi et al. concluded that “capillary blood glucose measurement by using glucometer is not recommended for patients in coma.”[1] In fact, there are many previous comparative studies between blood glucose measurement from capillary and venous blood samples. For sure, it is no doubt that the results cannot be the same. Nevertheless, there are several attempts to adjust the derived laboratory values. For example, Balaji et al. recently performed a comparative study between blood glucose measurement from capillary and venous blood samples for the diagnosis of gestational diabetes mellitus and proposed for new cut‐off value for interpretation of capillary blood glucose results.[2] In the present scenario proposed by Yaraghi et al., the coma is actually a critical condition. The rapid management is needed and the turnaround time for a laboratory test is the big issue. The use of capillary blood glucose measurement as point‐of‐care testing is the concept to correspond to the urgent need of laboratory results. The point‐of‐care glucose (POCG) testing is still considered useful. However, the problem of error can be expected. As proposed by Schifman et al., “Preanalytic factors associated with sampling capillary blood” is a big issue that the practitioner needs to concern.[3] If there is a good control, the difference can be little.[4] For the critical situation, the primary result from POCG might be used for patient management, and retesting to confirm critical results should also be parallel done.[3] Finally, it should be also noted that if there is no good quality management, the preanalytical error can be seen either in glucose measurement by capillary or in venous blood samples.[5]

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Capillary versus venous bedside blood glucose estimations.

OBJECTIVES To determine the mean difference and correlation between capillary and venous bedside glucose estimation in comparison to laboratory blood glucose analysis in emergency department (ED) patients. METHODS Blood glucose levels were synchronously analysed using a bedside blood glucometer on capillary and venous derived samples from consenting ED patients aged >12 years. The venous samp...

متن کامل

بررسی همخوانی نوارهای سنجش قند خون بتاچک با روش استاندارد

Diabetes mellitus (DM) is the commonest cause of renal failure, blindness and non traumatic amputation. According to ADA, prevention of DM complications is possible through monitoring and control of blood glucose levels.Methods: The Betachek strip, produced in Australia, is able to determine biood glucose level with no need for electronic glucometer devices.Results: In this study, we compared v...

متن کامل

The Effect of Isopropyl Alcohol and Chlorhexidine Gluconate on the Blood Glucose in Diabetic Patients Referring to the Emergency Department

Introduction: Diabetes is a metabolic disorder that can cause considerable disability and mortality. The aim of controlling diabetes is to normalize blood glucose levels to reduce the progression of vascular and neurological complications. Blood glucose control and reassurance are essential for planning health care. Objective: In the present study, the effect of local isopropyl alcohol and chlo...

متن کامل

مقایسه میزان همخوانی یافته‌های سنجش قندخون با استفاده از گلوکومتر ON CALL و گلوکوکارد با روش آزمایشگاهی استاندارد

Background: Diabetes Mellitus (DM) is one the most common chronic disease, with many complications including renal failure, blindness and non traumatic amputation. Prevention of complications is possible through monitoring and control of blood glucose levels. Considering how easy home blood glucose monitoring is, we decided to evaluate the performance of two available glucometers for detection...

متن کامل

Comparability of hemoglobin A1c level measured in capillary versus venous blood sample applying two point-of-care instruments

BACKGROUND The present study is designed to evaluate the validity of the measurement of capillary blood hemoglobin A1c levels in comparison with venous blood hemoglobin A1c. METHODS The data of this cross-sectional study are collected from a sample of 45 Iranian diabetic patients referred to one particular laboratory for the assessment of HbA1c level during a period from April to December 201...

متن کامل