Rapid determination of germanium and tin by ion chromatography

نویسندگان

  • Qun Sun
  • Huitong Wang
  • Shifen Mou
چکیده

A method was established for the simultaneous determination of germanium and tin in one run by ion chromatography. Using a selected eluent, Ge and Sn were separated on a bifunctional ion-exchange column, followed by a postcolumn chromogenic reaction and spectrophotometric detection at 520 nm. The whole procedure was completed within 5 min with high sensitivity and selectivity at the low-/zg/1 level. The results of real sample analysis were satisfactory.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

Development and Validation of an Ion Chromatography Method for Quantification of Ammonium Ions in STEALTH® Liposomes

Ammonium sulfate is one of the subsidiary components in the stealth liposome structure. The ratio of ammonium ion bound to liposome sphere to ammonium ions outside the liposome plays an important role in drug delivery formulation; accordingly, in order to quantify the ammonium ion in the liposome structure, a rapid and sensitive method was validated using a conductivity detector. Through this m...

متن کامل

Polymeric Membrane Sensor for Potentiometric Determination of Tin(II) Ions

Tin(II)-ion-selective electrode consisting of dibenzo-18-crown-6 (DB18C6) as an ionophore inPVC matrix was developed. The influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. The electrodeshowed a near Nernstian response for Sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27...

متن کامل

Mass Spectra of the Tetramethyl Compounds of Carbon Silicon , Germanium , Tin , and Lead 1 Vernon

Mass spectra of C(CI-I3)" Si(CI-I3)" Ge(CI-I3)" Sn(CI-I3)" and Pb (CI-Ia), were obtained with a Consolidated 21103 mass spectrometer. I sotopic abundan ces of carbon , si licon , germanium, tin, and lead were obtained from t he observed spectra and used to calculate the monoisotopic spectra. The mass spectra of t he Group IV tetramethyls a re qualitatively similar. The principal ion in each cas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002