The design and development of a finger joint simulator.
نویسنده
چکیده
Artificial finger joints lack the long-term clinical success seen with hip and knee prostheses. In part, this can be explained by the challenges of rheumatoid arthritis, a progressive disease which attacks surrounding tissues as well as the joint itself. Therefore, the natural finger joints' biomechanics are adversely affected, and consequently, this imbalance due to subluxing forces further challenges any prosthesis. Many different designs of finger prosthesis have been offered over a period of greater than 50 years. Most of these designs have failed, and it is likely that many of these failures could have been identified had the prostheses been appropriately tested prior to implantation into patients. While finger joint simulators have been designed, arguably only those from a single centre have been able to reproduce clinical-type failures of the finger prostheses tested in them. This article describes the design and development of a finger simulator at Durham University, UK. It explains and justifies the engineering decisions made and thus the evolution of the finger simulator. In vitro results and their linkage to clinical-type failures are outlined to help to show the effectiveness of the simulator. Failures of finger implants in vivo continue to occur, and the need for appropriate in vitro testing of finger prostheses remains strong.
منابع مشابه
Recurrent Dislocation of the Proximal Interphalangeal Joint of the Finger: A Rare Issue in Hand Surgery
Recurrent dislocation is not common in small joints. This report presents a new case of chronic recurrent dislocation of proximal interphalangeal joint of the finger in which soft tissue injuries have a role in the dislocation. The patient was a 23 years old man who had referred to our center because of recurrent dislocation of proximal interphalangeal joint of his right ring finger during spor...
متن کاملOptimization of fuzzy controller for an SMA-actuated artificial finger robot
The purpose of this paper is to design and optimize an intelligent fuzzy-logic controller for a three-degree of freedom (3DOF) artificial finger with shape-memory alloy (SMA) wire actuators. The robotic finger is constructed using three SMA wires as tendons to bend each phalanx of the finger around its revolute joint and three torsion springs which return the phalanxes to their original positio...
متن کاملMechatronic Hand Design with Integrated Mechanism in Palm for Efficiency Improve of the Finger.
One of the most important case in humanoid robot designing is hand, which it consider as an country development. High percentage of robot work quality depend on hand capability. A robot function increase with hand movement. One of important movement in artificial hand capability relate to fingers lateral movement. This case has more effect intake of special objects such as round shape or moving...
متن کاملDesign and Kinematic Analysis of a 4-DOF Serial-Parallel Manipulator for a Driving Simulator
This paper presents the kinematic analysis and the development of a 4-degree-of-freedom serial-parallel mechanism for large commercial vehicle driving simulators. The degrees of freedom are selected according to the target maneuvers and the structure of human motion perception organs. Several kinematic properties of parallel part of the mechanism under study are investigated, including the inve...
متن کاملDesign and Manufacturing of Jet to free Stream Simulator to Experimental Study of Interaction of Oblique Jet in Crossflow
The study of interactions of jet into cross flow at different longitudinal and transverse angles of jet was studied. The following components were designed and constructed: a low velocity wind tunnel to produce the uniform flow, a flat plate with a traverse injection system to simulate the jet injection, and a spatial rake to measure the total pressure. The tests were carried out at longitudina...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine
دوره 230 5 شماره
صفحات -