Haemostatic screening and identification of zebrafish mutants with coagulation pathway defects: an approach to identifying novel haemostatic genes in man.

نویسندگان

  • P Jagadeeswaran
  • M Gregory
  • S Johnson
  • B Thankavel
چکیده

Zebrafish were used as a model to study haemostasis, a vertebrate function of paramount importance. A limitation of the zebrafish model is the difficulty in assaying small amounts of blood to detect coagulation mutants. We report the use of a rapid total coagulation activity (TCA) assay to screen for coagulation defects in individual adult zebrafish. We screened the TCA in 1000 gynogenetic half-tetrad diploids derived from 86 clutches. Each clutch was from a single F1 female offspring of males mutagenized with ethylnitrosourea (ENU). We found 30-50% defective zebrafish among six clutches, consistent with a heritable defect. The assay developed here provided a rapid screen to detect overall coagulation defects. However, because of the limited amounts of plasma, we could not detect defects in specific pathways. Therefore, a novel, ultra-sensitive kinetic method was developed to identify specific pathway defects. To test whether the kinetic assay could be used as a screening tool, 1500 Florida wild-type zebrafish pairs were analysed for naturally occurring coagulation defects. We detected 30 fish with extrinsic pathway defects, but with intact common and intrinsic pathways. We conclude that it is now possible to identify specific coagulation pathway defects in zebrafish.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The role of PFA-100 testing in the investigation and management of haemostatic defects in children and adults.

The PFA-100 provides a simple global measure of high shear-dependent platelet function, and as such is not diagnostic or specific to any disorder. Prolonged closure times must be interpreted in conjunction with a full blood count, von Willebrand factor (VWF) screen and other platelet tests. The PFA-100 may also give false negative results with relatively common platelet defects. If clinical sus...

متن کامل

Red cell-derived microparticles (RMP) as haemostatic agent.

Among circulating cell-derived microparticles, those derived from red cells (RMP) have been least well investigated. To exploit potential haemostatic benefit of RMP, we developed a method of producing them in quantity, and here report on their haemostatic properties. High-pressure extrusion of washed RBC was employed to generate RMP. RMP were identified and enumerated by flow cytometry. Their s...

متن کامل

اثر هموستاتیک کلرید آلومینیوم در خونریزی کبدی ناشی از لاسراسیون: مطالعه مدل حیوانی

Background: Controlling parenchymal hemorrhage especially in liver parenchyma, despite all the progress in surgical science, is still one of the challenges surgeons face saving patients’ lives and there is a research challenge among researchers in this field to introduce a more effective method. This study attempts to determine the haemostatic effect of aluminum chloride and compare it with tha...

متن کامل

Haemostatic defects in cyanotic congenital heart disease.

An investigation of defects of the haemostatic mechanism in 41 children with cyanotic congenital heart disease concluded that such abnormalities were common and normally involved factors synthesised in the liver, that is the vitamin K dependent factors (rothrombin, factors VII and IX) and factor V. No evidence was found of activation of the coagulation or fibrinolytic systems. The defects can b...

متن کامل

Haemostatic failure in babies with rhesus isoimmunization.

Chessells, Judith M., and Wigglesworth, J. S. (1971). Archives of Disease in Childhood, 46, 37. Haemostatic failure in babies with rhesus isoimmunization. Platelet counts, fibrinogen levels, thrombotest, thromboplastin generation screening test, thrombin ratio, and titre of circulating fibrin degradation products, were measured in 30 infants with Rh isoimmunization, of whom 5 had a bleeding ten...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of haematology

دوره 110 4  شماره 

صفحات  -

تاریخ انتشار 2000