Absorption spectra of human fetal and adult oxyhemoglobin, de-oxyhemoglobin, carboxyhemoglobin, and methemoglobin.

نویسندگان

  • W G Zijlstra
  • A Buursma
  • W P Meeuwsen-van der Roest
چکیده

We determined the millimolar absorptivities of the four clinically relevant derivatives of fetal and adult human hemoglobin in the visible and near-infrared spectral range (450-1000 nm). As expected, spectral absorption curves of similar shape were found, but the small differences between fetal and adult hemoglobin absorptivity were important enough that they should be taken into account in multicomponent analysis of hemoglobin derivatives. Common pulse oximeters, however, involving light of 660 and 940 nm, are so insensitive to the presence of fetal hemoglobin that they can be used safely in neonates. The error in pulse oximetry caused by the presence of carboxyhemoglobin is insubstantial, but methemoglobin gives either an understimation or an overestimation at high or low oxygen saturation, respectively, the turning point being near 70% saturation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simplified determination of carboxyhemoglobin.

This spectrophotometric method for estimating carboxyhemoglobin is based on the production of a two-pigment mixture by reducing oxyhemoglobin and methemoglobin with sodium hydrosulfite . Absorbances of the pigment are measured at 420 and 432 nm. Protecting the solutions against exposure to air is unnecessary. Values are stable and reproducible when the solutions are buffered at pH 6.85.

متن کامل

Dynamic hyperinflation, intrinsic positive end-expiratory pressure, and respiratory rate.

In reviewing the article “Methemoglobinemia: Sudden Dyspnea and Oxygen Desaturation After Esophagoduodenoscopy,” in the August 2004 issue of RESPIRATORY CARE,1 I found the article suggested that, during the esophagoduodenoscopy procedure the patient’s blood oxygen saturation (measured via pulse oximetry) began to drop rapidly, and a saturation of 54% registered on the pulse oximeter while the p...

متن کامل

Methods for measuring plasma hemoglobin in micromolar concentration compared.

Of eight methods examined for measuring plasma hemoglobin in micromolar concentration, all exhibited acceptable linearity, reproducibility, and concurrence except when specimens were icteric or lipemic or contained methemoglobin or methemalbumin. Measurement of absorbance at 578 nm with an Allen correction permits precise assay of plasma oxyhemoglobin concentration as low as 0.01 g/L (1 mg/dL, ...

متن کامل

Methemoglobinemia and Pulse Oximetry

In reviewing the article “Methemoglobinemia: Sudden Dyspnea and Oxygen Desaturation After Esophagoduodenoscopy,” in the August 2004 issue of RESPIRATORY CARE,1 I found the article suggested that, during the esophagoduodenoscopy procedure the patient’s blood oxygen saturation (measured via pulse oximetry) began to drop rapidly, and a saturation of 54% registered on the pulse oximeter while the p...

متن کامل

Pulse Oximetry in Acute Respiratory Failure: What Should Be Expected?-Reply.

To the Editor: In the April issue of RESPIRATORY CARE, Amalakanti and Pentakota1 present a comparison of arterial oxygen saturation values between a 2-wavelength pulse oximeter and blood gas multi-wavelength hemoximetry in COPD subjects with acute respiratory failure. The authors conclude that the 2-wavelength pulse oximeter significantly overestimates arterial oxygen saturation and that COPD a...

متن کامل