In vivo bone response and interfacial properties of titanium-alloy implant with different designs in rabbit model with time.

نویسندگان

  • Abhijit Chakraborty
  • Biswanath Kundu
  • Debabrata Basu
  • Tamal Kanti Pal
  • Samit Kumar Nandi
چکیده

BACKGROUND Using implants for dental applications are well-accepted procedures as one of the solutions for periodontal defect repair. Suitable design and materials, their reaction with the surrounding hard tissues and interfacial biomechanical properties are still considered to be the primary criteria which need to be addressed systematically. In the present study, a thorough and systemic approach was made to identify a suitable implant, considering the above criteria after both in vitro and in vivo animal trials. MATERIALS AND METHODS Titanium alloy (Ti-6Al-4V) implants, with thread and without thread models, were implanted to the mid-metaphysial portion of the tibia of the right hind leg of three white Australian Chinchilla rabbit species and their effects and response to the surrounding bone were investigated. Parameters studied included hematological and biochemical features (serum alkaline phosphatase and calcium), both preoperatively and postoperatively, consecutively for 7 days and after 1-3 months. The interfacial integrity and compositional variation along the interface were studied using scanning electron microscope (SEM) with energy dispersive analysis of X-ray (EDAX) and histopathology from 1 to 3 months consecutively. Finally, biomechanical properties were studied with the help of push-out test. RESULTS Bone remineralization started through the process of electro-physiological ionic exchanges, which helps in formation of osteoblastic cells in the area of bony injury. The SEM-EDAX results confirmed the initial stability for the Ti (with thread) implant, but the regeneration of new bone formation was faster in the case of Ti (Without thread) implant, and hence could be used for faster healing. These have also been substantiated through push-out and histopathlogical tests. CONCLUSION From the physico-chemical and biomechanical observations, it was found that that smooth type implants were well accepted in the physiological condition although chances of elemental leaching from the surface were also observed. Increase of the surface roughness can help into the formation of physico-chemical bondage with the surrounding hard tissues.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The axisymmetric computational study of a femoral component to analysis the effect of titanium alloy and diameter variation.

This work presents a numerical approach in order to predict the influence of implant material stiffness in a femoral component design when submitted in compression. The implant success depends on the transferred load to the neighboring bone. The finite element method can be used to analysis the stress and strain distribution in the femoral component allowing to improve the implant selection. Fo...

متن کامل

Bone Tissue Response to Plasma Sprayed Hydroxyapatite Coatings: An In Vivo Study on Rabbit Femoral Condyles

     In this study, hydroxyapatite was coated on titanium substrates by plasma spraying process. A well-known porous and lamellar microstructure was found in the lateral a...

متن کامل

Fatigue and corrosion fatigue properties of Ti-6Al-4V implant grade titanium alloy in Ringer solution

Nowadays modification of metallic biomaterials which are used as implants for bone and hard tissues replacement is considered as an important subject. In the current study, corrosion fatigue properties of Ti-6Al-4V alloy investigated via Rotating-Bending standard test method and then, the results compared with the fatigue properties of the specimens tested in the same conditions. Scanning elect...

متن کامل

Interfacial shear strength of bioactive-coated carbon fiber reinforced polyetheretherketone after in vivo implantation.

Despite the excellent osseointegration of carbon-fiber-reinforced polyetheretherketone (CFR/PEEK) with a surface hydroxyapatite (HA) coating, the bone-implant interfacial shear strength of HA-coated CFR/PEEK after osseointegration is unclear. We examined the interfacial shear strength of HA-coated CFR/PEEK implants after in vivo implantation in a rabbit femur-implant pull-out test model. HA coa...

متن کامل

اثر امواج فراصوتی کم توان بر رشد استخوان در داخل کانال ایمپلانت تیتانیومی

The effect of ultrasound waves with low intensity on reducing the time of repair and healing of bone fracture has been known. The present research was undertaken to investigate the effect of ultrasound waves on acceleration of bone growth and, finally, on repair and healing of surgical area using in-vivo animal experiment. In this study, 20 titanium implants with proper dimensions wer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Indian journal of dental research : official publication of Indian Society for Dental Research

دوره 22 2  شماره 

صفحات  -

تاریخ انتشار 2011