Seasonal changes of 24-hour intraocular pressure rhythm in healthy Shanghai population

نویسندگان

  • Jingyi Cheng
  • Ming Xiao
  • Huan Xu
  • Shaobin Fang
  • Xu Chen
  • Xiangmei Kong
  • Xinghuai Sun
چکیده

The aim of the present study was to investigate and compare the 24-hour intraocular pressure (IOP) rhythms in winter and summer in the healthy population of Shanghai, China.This is a cross-sectional study in which 24-hour IOP measurements were taken for all eligible healthy volunteers in winter and summer, respectively, and the temperature, hours of sunlight (sunlight time), and circulatory parameters, including heart rate, systolic blood pressure, and diastolic blood pressure, were also recorded. The 24-hour IOP curves and IOP parameters (mean, peak, trough, and fluctuation of IOP together with the diurnal-to-nocturnal IOP change) in winter and summer were obtained and compared. The magnitude of IOP changes from summer to winter was also calculated.A total of 29 participants (58 eyes), 14 (48.28%) male and 15 (51.72%) female, aged 43.66 ± 12.20 (19-61) years, were considered eligible for this study. Generally, IOP decreased progressively before noon, increased notably in the nocturnal period, and peaked at 12:00 AM in winter and at 2:00 AM in summer. The pattern of 24-hour IOP in winter and summer was significantly different (P = 0.002). The average IOPs from 4:00 PM to 8:00 AM, except for 6:00 AM, were significantly higher in winter (P < 0.05). However, no significant differences were shown after adjusting for temperature and/or sunlight time. From summer to winter, the extent of IOP increase was mostly around 0 to 3 mm Hg, and the IOPs increased more significantly in the nocturnal period than in the diurnal period (P = 0.05).The 24-hour IOP rhythms were different in winter and summer, with higher IOP level in winter. Temperature and sunlight time, which are independent of heart rate and blood pressure, affected the 24-hour IOP rhythms in healthy people in Shanghai, China. Further investigations are expected for the rhythm of some endogenous substance secretion and the inner mechanism of regulation of IOP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

24-hour intraocular pressure rhythm in young healthy subjects evaluated with continuous monitoring using a contact lens sensor.

IMPORTANCE This study evaluates a new device that has been proposed to continuously monitor intraocular pressure (IOP) over 24 hours. OBJECTIVE To evaluate 24-hour IOP rhythm reproducibility during repeated continuous 24-hour IOP monitoring with noncontact tonometry (NCT) and a contact lens sensor (CLS) in healthy participants. DESIGN, SETTING, AND PARTICIPANTS Cross-sectional study of 12 y...

متن کامل

Effect of 24-hour corneal biomechanical changes on intraocular pressure measurement.

PURPOSE To study 24-hour changes of corneal biomechanical properties and their influences on measurement of intraocular pressure (IOP). METHODS Fifteen healthy young volunteers (age range, 20-25 years) were housed for 1 day in a sleep laboratory. Sitting and supine central corneal thickness (CCT) were measured every 2 hours with an ultrasonic pachymeter. Sitting IOP and corneal hysteresis, an...

متن کامل

Hourly awakening vs continuous contact lens sensor measurements of 24-hour intraocular pressure: effect on sleep macrostructure and intraocular pressure rhythm.

IMPORTANCE All studies of 24-hour intraocular pressure (IOP) rhythm conducted to date have used repeated IOP measurements requiring nocturnal awakenings, potentially disturbing sleep macrostructure. OBJECTIVE To evaluate the effects on sleep architecture and IOP rhythm of hourly awakening vs a contact lens sensor (CLS) to continuously monitor IOP without awakening. DESIGN, SETTING, AND PART...

متن کامل

Frequent loss of nyctohemeral rhythm of intraocular pressure restored by nCPAP treatment in patients with severe apnea.

OBJECTIVE To assess 24-hour intraocular pressure (IOP) and ocular perfusion pressure rhythms in newly diagnosed apneic patients before and after nasal continuous positive airway pressure (nCPAP) treatment. METHODS Intraocular pressure (using a Tonopen XL) and ambulatory blood pressure, measured hourly for 24 hours, were analyzed in 18 consecutive patients with obstructive sleep apnea for nyct...

متن کامل

Instability of 24-hour intraocular pressure fluctuation in healthy young subjects: a prospective, cross-sectional study

BACKGROUND Elevated intraocular pressure (IOP) is a major risk factor for the development and/or progression of glaucoma, and a large diurnal IOP fluctuation has been identified as an independent risk factor of glaucoma progression. However, most previous studies have not considered the repeatability of 24-hour IOP measurements. The aim of this study was to evaluate the instability of 24-hour I...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 95  شماره 

صفحات  -

تاریخ انتشار 2016