Effect of Seed Size and Density on Near-infrared Transmittance Analysis of Corn and Soybeans
نویسندگان
چکیده
Soybean physical and chemical properties changed by size (from 4.8 to 8.8 mm diameter), but soybean size and seed density did not affect the protein and oil determination accuracy of three near-infrared transmission analyzers. Corn samples were also separated by size and kernel density. Changes in corn kernel density and size introduced small errors in near-infrared transmission protein, oil, and starch measurements. In corn protein, the maximum error was about ±0.2% points. A robust calibration set is needed to eliminate the weak seed weight and density effects, as well as to support the corn density calibration for near-infrared analyzers.
منابع مشابه
Measurement of inorganic phosphorus in soybeans with near-infrared spectroscopy.
This study explored the feasibility of near-infrared (NIR) quantitative and qualitative models for soybean inorganic phosphorus (Pi), which is complementary to phytic acid, a component of nutritional and environmental importance. Spectra, consisting of diffuse reflectance (1100-2500 nm) of ground meal and single-bean transmittance (600-1900 nm) of whole seed, were collected on 191 recombinant i...
متن کاملFeasibility of near infrared spectroscopy for analyzing corn kernel damage and viability of soybean and corn kernels
The current US corn grading system accounts for the portion of damaged kernels, measured by timeconsuming and inaccurate visual inspection. Near infrared spectroscopy (NIRS), a non-destructive and fast analytical method, was tested as a tool for discriminating corn kernels with heat and frost damage. Four classification algorithms were utilized: Partial least squares discriminant analysis (PLS-...
متن کاملDetermining Blood Glucose Concentration using Near Infrared Spectroscopy: Early Findings
Introduction: Diabetes mellitus is one of the diseases that have grown dramatically in today's societies. People with diabetes should continuously measure their blood glucose level. Continuous blood glucose measurement by commonly used methods is painful and difficult. On the other hand, mobile phone can be a useful tool for accessing physicians and telemedicine services more easily. The aim of...
متن کاملDetermining Blood Glucose Concentration using Near Infrared Spectroscopy: Early Findings
Introduction: Diabetes mellitus is one of the diseases that have grown dramatically in today's societies. People with diabetes should continuously measure their blood glucose level. Continuous blood glucose measurement by commonly used methods is painful and difficult. On the other hand, mobile phone can be a useful tool for accessing physicians and telemedicine services more easily. The aim of...
متن کاملCorn Density Measurement by Near-infrared Transmittance
A corn density calibration was developed for a near-infrared transmittance instrument (Infratec 1225). The calibration sample set included 96 corn samples grown in various locations of the United States. Samples were selected by principal component analysis (PCA) from a larger set of 410 samples, representing the 1986 through 1992 crop years. Samples for instrument and temperature stabilization...
متن کامل