Cryogenic zone compression for the measurement of dioxins in human serum by isotope dilution at the attogram level using modulated gas chromatography coupled to high resolution magnetic sector mass spectrometry.
نویسندگان
چکیده
A liquid nitrogen jet-cooled thermal modulator dedicated to comprehensive two-dimensional gas chromatography has been mounted in a GC oven coupled to a high resolution magnetic sector mass spectrometry instrument. The data acquisition parameters of the slow double-focusing magnetic sector MS instrument have been optimized to accommodate the description of the narrow modulated GC peaks. Acquisition rates were increased to 20Hz, while maintaining high mass resolution. Selected ion monitoring (SIM) descriptors, typically including several ions for both native and labeled analytes, were thus reduced to one or two to ensure enough MS cycle time. For maximization of the sensitivity enhancement due to cryogenic zone compression (CZC), the entire GC peak of interest was trapped and remobilized in one event. Optimization of the method resulted in the ability to detect low attogram (ag) amounts of 2,3,7,8-tetrachlorodibenzo-p-dioxin (2,3,7,8-TCDD) (313ag gives a S/N of 400:1), a level that had not yet been attained using classical GC-HRMS. An isotope-dilution calibration curve was constructed using (13)C(12)-2,3,7,8-TCDD as the internal standard over the range of 500ag/μL to 35,000ag/μL (R(2)=0.9953). Analyses of a standard natural human reference serum-matrix NIST SRM 1589a containing 223ag of 1,2,3,7,8-pentachlorodibenzo-p-dioxin (1,2,3,7,8-PeCDD) (70% recovery rate assumed) resulted in a peak with a S/N of 188:1 (4 sigma, m/z=355.8546). Measurement of 2,2-bis (4-chlorophenyl-1,1,1-trichloroethane) (DDE) and 2,2',4,4',5,5'-hexabromobiphenyl (BB-153) in human dried-blood spot (DBS) samples is also reported to illustrate the usefulness of such a sensitive technique. Finally, some of the challenges related to sample preparation, blank levels, and to the fact of measuring of such a limited number of molecules (less than 600,000 TCDD molecules) are discussed.
منابع مشابه
High-throughput biomonitoring of dioxins and polychlorinated biphenyls at the sub-picogram level in human serum.
We report on the use of a state-of-the-art method for the measurement of selected polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans and polychlorinated biphenyls in human serum specimens. The sample preparation procedure is based on manual small size solid-phase extraction (SPE) followed by automated clean-up and fractionation using multi-sorbent liquid chromatography columns. SP...
متن کاملRecent advances in mass spectrometric measurement of dioxins.
Past years, many efforts have been dedicated to the development of alternative analytical methods for the measurement of dioxins in various types of matrices. Polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and polychlorinated biphenyls (PCBs) are compounds that are present in samples at part-per-billion (ppb) or part-per-trillion (ppt) level. Their measurement...
متن کاملMeasurement of urea in human serum by isotope dilution mass spectrometry: a reference procedure.
BACKGROUND A reference measurement procedure is needed to demonstrate the traceability of results of urea measurements in human serum. We developed a measurement procedure using the principle of isotope dilution gas chromatography/mass spectrometry. METHODS [(13)C,(15)N(2)]Urea as internal standard was added to a serum sample and equilibrated with endogenous nonlabeled urea. For the preparati...
متن کاملA Comparison of GC-ICP-MS and HPLC-ICP-MS for the Analysis of Organotin Compounds Application
An inductively coupled plasma mass spectrometer (ICP-MS) was used as a detector for gas chromatography (GC) and high performance liquid chromatography (HPLC) analysis of organotin compounds. ICP-MS is a highly sensitive detector with detection limits in the pg ng range, as well as enabling calibration by isotope dilution mass spectrometry (IDMS). Calibrating using isotopically labeled organotin...
متن کاملDetermination of creatinine in human serum by isotope dilution-mass spectrometry. Definitive methods in clinical chemistry, IV.
A method for the determination of creatinine in human serum by isotope dilution-mass spectrometry is described. The analytical procedure comprises the following steps: Addition of [13C,15N2 )creatinine to the serum sample; ion exchange chromatography on the cation exchange resin AG 50W-X2; formation of the trimethylsilyl derivative; gas liquid chromatography-mass spectrometry (GC-MS); selected ...