Evaluation of Cone Beam Computed Tomography (CBCT) System: Comparison with Intraoral Periapical Radiography in Proximal Caries Detection
نویسندگان
چکیده
BACKGROUND AND AIMS With the introduction of Cone Beam Computed Tomography (CBCT) in dentistry, a question has been raised whether the technique significantly increases the diagnostic accuracy in comparison with other techniques or not. Therefore, the present study was undertaken to assess the accuracy of CBCT modality in detecting proximal carious lesions as compared to conventional periapical radiographs. MATERIALS AND METHODS This diagnostic study was carried out on 84 human extracted molars and premolars. The teeth were mounted and divided in 28 blocks of 3 teeth. Periapical and CBCT images of teeth were obtained. Five observers scored the images for the detection of proximal carious lesions using a 2-point scale (caries, present; caries, absent). The gold standard was determined by histopathologic sections. Sensitivity, specificity, PPV, NPV and receiver operating charac-teristics (ROC) curves were traced for observers in both systems. The results were analyzed by paired t-test. RESULTS The area under the ROC curve, sensitivity, specificity, accuracy, positive and negative predictive values of CBCT images were 0.568, 0.835, 0.637, 0.714, 0.598 and 0.856, respectively. These parameters were 0.432, 0.837, 0.722, 0.77, 0.687 and 0.858 for the periapical conventional technique, respectively. CONCLUSION The CBCT images did not enhance detection of proximal caries in comparison with periapical images.
منابع مشابه
Comparison of cone beam computed tomography and digital radiography in detection of pulpal exposure in external cervical root resorption
Background and Aims: Pulpal exposures originated from the external cervical root resorptions have major effects on the treatment and prognosis. Therefore, the aim of this study was performed to compare the two different imaging systems-digital radiography with PSP (Photostimulable Phosphor) sensor in three horizontal different views and CBCT (cone beam computed tomography) images to assess the ...
متن کاملComparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects
Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects. Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...
متن کاملComparison of Cone Beam Computerized Tomography and Phosphor Storage Plate in Detecting Artificial Buccal Recurrent Caries
Introduction Recurrent or secondary caries develops at the margin of restorations and causes restorative failure. We conducted this study to compare the performance of Phosphor Storage Plate (PSP) and Cone Beam Computed Tomography (CBCT) scan in detecting buccal recurrent caries under amalgam and composite resin restorations. Materials and Methods Class V cavities were prepared on the buccal...
متن کاملDetection of periapical bone defects in human jaws using cone beam computed tomography and intraoral radiography.
AIM To compare the diagnostic accuracy of intraoral digital periapical radiography with that of cone beam computed tomography (CBCT) for the detection of artificial periapical bone defects in dry human jaws. METHODOLOGY Small and large artificial periapical lesions were prepared in the periapical region of the distal root of six molar teeth in human mandibles. Scans and radiographs were taken...
متن کاملComparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha
Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...
متن کامل