Thyrotoxicosis-facilitated bridge to recovery with a continuous-flow left ventricular assist device.

نویسندگان

  • George V Letsou
  • Stephane Reverdin
  • O H Frazier
چکیده

The HeartMate II is a continuous-flow left ventricular assist device that can be explanted from patients after cardiac recovery. We implanted a HeartMate II in a 21-year-old man who had idiopathic cardiomyopathy. A year later, he developed thyrotoxicosis, presumably secondary to amiodarone administered for ventricular fibrillation. Four months after the diagnosis of thyrotoxicosis, thyroid hormone levels had returned to normal, and native cardiac function had improved remarkably. After a support period of 24 months, the HeartMate II was explanted. Six years later, the patient continues to be in New York Heart Association functional Class I. Amiodarone-induced thyrotoxicosis may have contributed to myocardial recovery.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Myocardial recovery in peri-partum cardiomyopathy after continuous flow left ventricular assist device

Left ventricular assist devices (LVADs) offer effective therapy for severe heart failure (HF) as bridge to transplantation or destination therapy. Rarely, the sustained unloading provided by the LVAD has led to cardiac reverse remodelling and recovery, permitting explantation of the device. We describe the clinical course of a patient with severe peri-partum cardiomyopathy (PPCM) rescued with a...

متن کامل

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)

Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...

متن کامل

Cardiac recovery during continuous-flow left ventricular assist device support: some good news from across the Atlantic.

In this issue of Circulation, Birks et al1 report their recent experience using the combination of continuous-flow (CF) circulatory support and pharmacological therapy to treat advanced heart failure in patients requiring left ventricular assist device (LVAD) support. Thirty-three patients underwent HeartMate II (HMII) LVAD implantation at Harefield hospital during the 3-year study period. Twen...

متن کامل

Apical pseudoaneurysm following continuous flow left ventricular assist device placement.

The HeartMate II continuous flow left ventricular assist device (LVAD) (Thoratec Inc) provides circulatory support for patients with medically refractory systolic heart failure as both a bridge to transplantation and destination therapy. Although left ventricular apical pseudoaneurysm has rarely been reported with first-generation pulsatile flow LVADs, this has not been previously reported with...