BACKGROUNDS Drug-eluting stents (DES) with biodegradable polymers have been developed to address the risk of thrombosis associated with first-generation DES. We aimed to determine the efficacy and safety of biodegradable polymer biolimus-eluting stents (BES) versus durable polymer DES. METHODS Systematic database searches of MEDLINE (1950 to June 2013), EMBASE (1966 to June 2013), the Cochrane Central Register of Controlled Trials (Issue 6 of 12, June 2013), and a review of related literature were conducted. All randomized controlled trials comparing biodegradable polymer BES versus durable polymer DES were included. RESULTS Eight randomized controlled trials investigating 11,015 patients undergoing percutaneous coronary interventions were included in the meta-analysis. The risk of major adverse cardiac events did not differ significantly between the patients treated with the biodegradable polymer BES and the durable polymer DES (Relative risk [RR], 0.970; 95% CI, 0.848-1.111; p = 0.662). However, biodegradable polymer BES was associated with reduced risk of very late ST compared with the durable polymer DES, while the risk of early or late ST was similar (RR for early or late ST, 1.167; 95% CI 0.755-1.802; p = 0.487; RR 0.273; 95% CI 0.115-0.652; p = 0.003; p for interaction = 0.003). CONCLUSIONS In this meta-analysis of randomized controlled trials, treatments with biodegradable polymer BES did not significantly reduce the risk of major adverse cardiac events, but demonstrated a significantly lower risk of very late ST when compared to durable polymer DES. This conclusion requires confirmation by further studies with long-term follow-up. PROSPERO REGISTER NUMBER http://www.crd.york.ac.uk/PROSPERO/display_record.asp?ID=CRD42013004364#.UnM2lfmsj6J.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Safety and efficacy outcomes of first and second generation durable polymer drug eluting stents and biodegradable polymer biolimus eluting stents in clinical practice: comprehensive network meta-analysis

OBJECTIVES To investigate the safety and efficacy of durable polymer drug eluting stents (DES) and biodegradable polymer biolimus eluting stents (biolimus-ES). DESIGN Network meta-analysis of randomised controlled trials. DATA SOURCES AND STUDY SELECTION Medline, Google Scholar, Embase, and Cochrane Central Register of Controlled Trials (CENTRAL) database search for randomised controlled tr...

متن کامل

Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis

OBJECTIVE To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. DESIGN Mixed treatment comparison meta-analysis of 258,544 patient years of follow-up from randomized trials. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and Central were searched for randomized trials comparing any of the Fo...

متن کامل

Baremetal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis OPEN ACCESS

Objective To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. Design Mixed treatment comparison meta-analysis of 258 544 patient years of follow-up from randomized trials. Data sources and study selection PubMed, Embase, and Central were searched for randomized trials comparing any of the Food a...

متن کامل

Biodegradable-polymer drug-eluting stents vs. bare metal stents vs. durable-polymer drug-eluting stents: a systematic review and Bayesian approach network meta-analysis.

BACKGROUND The aim of this study was to compare the safety and efficacy of biodegradable-polymer (BP) drug-eluting stents (DES), bare metal stents (BMS), and durable-polymer DES in patients undergoing coronary revascularization, we performed a systematic review and network meta-analysis using a Bayesian framework. METHODS AND RESULTS Study stents included BMS, paclitaxel-eluting (PES), siroli...

متن کامل

Two-year outcome of a randomized trial comparing second-generation drug-eluting stents using biodegradable or durable polymer.

Two-Year Outcome of a Randomized Trial Comparing Second-Generation Drug-Eluting Stents Using Biodegradable or Durable Polymer Recentnetworkmeta-analyseshave raisedconcerns about the safety of biodegradable polymerdrug-eluting stents (BP-DES) compared with durable polymer everolimus-eluting stents (DP-EES).1-3 The NOBORI Biolimus-Eluting vs XIENCE/ PROMUSEverolimus-ElutingStentTrial (NEXT) is a9...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013