Slide-based ergometer rowing: effects on force production and neuromuscular activity.

نویسندگان

  • A Vinther
  • T Alkjaer
  • I-L Kanstrup
  • B Zerahn
  • C Ekdahl
  • K Jensen
  • A Holsgaard-Larsen
  • P Aagaard
چکیده

Force production profile and neuromuscular activity during slide-based and stationary ergometer rowing at standardized submaximal power output were compared in 14 male and 8 female National Team rowers. Surface electromyography (EMG) was obtained in selected thoracic and leg muscles along with synchronous measurement of handle force and rate of force development (RFD). Compared to stationary conditions, slide-based peak force decreased by 76 (57-95) N (mean 95% CI) in males (P < 0.001) and 20 (8-31) N (P < 0.05) in females. Stroke rate increased (+10.7%) and late-phase RFD decreased (-20.7%) in males (P < 0.05). Neuromuscular activity in m. vastus lateralis decreased in the initial drive phase from 59% to 51% of EMG max in males and from 57% to 52% in females (P < 0.01-0.05), while also decreasing in the late recovery phase from 20% to 7% in males and 17% to 7% in females (P < 0.01). Peak force and maximal neuromuscular activity in the shoulder retractors always occurred in the second quartile of the drive phase. In conclusion, peak force and late-phase RFD (males) decreased and stroke rate increased (males) during slide-based compared to stationary ergometer rowing, potentially reducing the risk of overuse injury. Neuromuscular activity was more affected in leg muscles than thoracic muscles by slide-based ergometer rowing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of rowing on a concept 2 stationary and dynamic ergometer.

Biomechanical and physiological responses to rowing 1000 m at a power output equivalent to a 2000 m race were compared in 34 collegiate rowers (17 women, 17 men) rowing on a stationary and dynamic Concept 2 ergometer. Stroke ratio, peak handle force, rate of force development, impulse, and respiratory exchange ratio decreased by 15.7, 14.8, 10.9, 10.2 and 1.9%, respectively, on the dynamic ergo...

متن کامل

The effect of ergometer design on rowing stroke mechanics.

The effect of rowing ergometer design upon power delivery and coordination patterns of the rowing stroke was analyzed for 14 elite rowers. Rowers were tested in three ergometer conditions: the fixed stretcher Concept2c ergometer, the Concept2c ergometer mounted on sliding rails, and the sliding stretcher RowPerfect ergometer. Ergometers were instrumented to measure the external force generated ...

متن کامل

Analysis of Lower Limb Muscle Function in Ergometer Rowing

In an effort to seek further understanding of lower limb muscle function in the rowing movement, an electromyographic analysis was undertaken of rowers rowing on a Gjessing ergometer. A strain gauged transducer was inserted in the ergometer linkage between handle and flywheel to detect pulling force. Electrodes were placed on the following lower limb muscles: gluteus maximus, biceps femoris, re...

متن کامل

The RowPerfect ergometer: a training aid for on-water single scull rowing.

The purpose of this study was to compare rowing technique on the dynamic RowPerfect ergometer with a single scull. Eight national-level rowers performed on both the RowPerfect ergometer and in a single scull over 500 m, at rates of 24, 26, and 28 strokes/minute. Blade force and oar angle (on-water) and handle force and stroke length (on the ergometer) were measured. Both force and stroke angle/...

متن کامل

Muscular coordination of the lower extremities of oarsmen during ergometer rowing.

In sweep-oar rowers, asymmetrical force production of the legs is a known phenomenon. The purpose of this study was to investigate the muscular activity of the legs that may cause this asymmetry even when oarsmen perform a symmetrical endurance task. Seven male young elite oarsmen performed an all-out 2000-m test on a rowing ergometer. During stroke kinematics, myoelectric activity of six muscl...