Analytic inaccuracy resulting from hematology specimen characteristics. Three cases of clinically misleading artifacts affecting white blood cell and platelet counts.

نویسنده

  • R A Savage
چکیده

Sporadically, hematology analyzers generate grossly erroneous results for one or several parameters of the complete blood count (CBC) because of a characteristic or peculiarity of an individual patient specimen. This article presents three cases of relatively less well-known analytic errors of this sort, falsely elevating white blood cell count and platelet count and decreasing total white blood cell count, as determined on a Coulter Aperture Impedence Analyzer. The type of alteration in the CBC parameters and the instrument histogram abnormalities seen in each of these different types of analytic inaccuracy are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Association between CRP Level on Admission Day and Length of Hospitalization and Engraftment in Patients Undergoing Autologous Hematopoietic Stem Cell Transplantation

 Background and purpose: Several studies investigated the role of C-reactive protein (CRP) during transplantation and inflammation, and clinical outcomes after stem cell transplantation. In this study, we examined the relationship between the earliest CRP level on admission day, and the first outcome after transplantation, myeloid and platelet engraftment, and the length of hospitalization in p...

متن کامل

Effects of pre-analytical handling on selected canine hematological parameters evaluated by automatic analyzer

To assess the effects of pre-analytical handling (storage time and temperature) on selected hematological parameters, whole blood samples were collected in EDTA coated tubes from each of 30 clinically normal male adult beagle dogs. Each sample was separated in 2 aliquots, of which one was stored in ambient temperature (25 ˚C) and the other one was refrigerated (2 to 4 ˚C). Complete blood counts...

متن کامل

Determination of Platelet and White Blood Cell Counts from Peripheral Blood Smear: An Indispensable Method in Under-resourced Laboratories

Objective: Blood smear examination serves as a quality control tool in verifying the results generated by the automated analyzer and identification of abnormal or immature cells amongst other functions. This study was undertaken to estimate platelet and White Blood Cell (WBC) counts from Peripheral Blood Smear (PBS) and to correlate them with the results from automated method. Materials and Met...

متن کامل

Laboratory identification of cryoglobulinemia from automated blood cell counts, fresh blood samples, and blood films.

Four cases showing different means to detect cryoglobulins are reported: effects on blood cell counts performed on 2 technologically different automated hematology instruments and microscopic features in fresh blood samples and on May-Grünwald-Giemsa-stained bloodfilms. These cases were chosen for their instructive value in depicting all artifacts associated with cryoglobulins. Laboratory recog...

متن کامل

Changes in Some Hematology Parameters in poisoning with Rice Tablet (Aluminum Phosphide)

Abstract      Background and Objective: Aluminum Phosphide (ALP) is a solid non-organic phosphide with dark gray or dark yellow crystals. It reacts with stomach acid after ingestion and causes phosphine gas to be released. It is thought that phosphine causes toxicity from enzymatic interference and may even lead to cell death. This study aimed to investigate the eff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of clinical pathology

دوره 92 3  شماره 

صفحات  -

تاریخ انتشار 1989