Pseudotumor due to metallosis after total elbow arthroplasty

نویسندگان

  • Roberto Rotini
  • Graziano Bettelli
  • Michele Cavaciocchi
  • Lucia Savarino
چکیده

The incidence of primary total elbow arthroplasty (TEA) in young patients is increasing. The indications for revision surgery are also rising. Here, we report a rare case of pseudotumor detected in a patient 16 years after TEA. Intraoperative findings revealed a necrotic mass characterized by a conspicuous metallosis in the soft tissues around the prosthesis, which caused ulnar nerve dislocation. Due to this anatomical change, a lesion of the nerve was accidentally produced during revision surgery. The case report emphasizes that the indications for elbow replacement, as well as the patient education about the permanent physical limitations, should be carefully considered. Moreover, the high risks of complications related to the revision procedure and pseudotumor removal need to be addressed before surgery. The technique should be done carefully and a preliminary thorough imaging should be performed, since a newly formed mass can cause significant distortion of the anatomy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Metallosis in revision total elbow arthroplasty. Complications and staging method.

Although total elbow arthroplasty is a reliable treatment method for the arthritic joint, revision is necessary if loosening, instability, wear, fracture or infection occurs. We report 12 patients with 19 months (10-29) follow-up after revision arthroplasty for painful loosening in six cases, periprosthetic fracture in three, gross instability in one and skin perforation with possible infection...

متن کامل

A Rare Case of Pseudotumor Formation following Total Knee Arthroplasty

A 59 year old man who had undergone left total knee arthroplasty in 2008 presented with a 5 month history of left knee pain and persistent swelling. Workup for infection was negative and the patient was suspected to be suffering from particle disease and chronic synovitis. Imaging revealed an internally rotated tibial component. Intraoperative findings revealed extensive polyethylene wear with ...

متن کامل

The Result of Revision Total Hip Arthroplasty in Patients with Metallosis Following a Catastrophic Failure of a Polyethylene Liner

BACKGROUND Wear cannot be completely prevented after total hip arthroplasty. If severe polyethylene (PE) liner wear develops, the so-called catastrophic failure occurs and metallosis develops. We postulated that longevity of the new implant may be affected after revision surgery for metallosis following a catastrophic failure of a PE liner due to the substantial amount of PE wear particles and ...

متن کامل

Wear debris pseudotumor following total knee arthroplasty: a case report

INTRODUCTION In patients who have undergone a total joint replacement, any mass occurring in or adjacent to the joint needs thorough investigation and a wear debris-induced cyst should be suspected. CASE PRESENTATION An 81-year-old man presented with a painful and enlarging mass at the popliteal fossa and calf of his right knee. He had had a total right knee replacement seven years previously...

متن کامل

Metallosis: CT findings in a total hip arthroplasty

We report a case of a 50-year-old man with extensive metallosis 20 years after right total hip arthroplasty. CT demonstrated osteolysis and radiodense debris surrounding the right hip joint. Although the radiographic appearance of metallosis has been well documented in the literature, the CT appearance of metallosis after total hip arthroplasty has been only sparsely described.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 51  شماره 

صفحات  -

تاریخ انتشار 2017