Contrast mechanisms in polarization-sensitive Mueller-matrix optical coherence tomography and application in burn imaging.
نویسندگان
چکیده
We investigate the various contrast mechanisms provided by polarization-sensitive (PS) Mueller-matrix optical coherence tomography (OCT). Our PS multichannel Mueller-matrix OCT is the first, to our knowledge, to offer simultaneously comprehensive polarization-contrast mechanisms, including the amplitude of birefringence, the orientation of birefringence, and the diattenuation in addition to the polarization-independent intensity contrast, all of which can be extracted from the measured Jones or the equivalent Mueller matrix. Theoretical analysis shows that when diattenuation is negligible, the round-trip Jones matrix represents a linear retarder, which is the foundation of conventional PS-OCT, and can be calculated with a single incident polarization state, although the one-way Jones matrix generally represents an elliptical retarder; otherwise, two incident polarization states are needed. The experimental results obtained from rat skin samples, which conform well with the histology, show that Mueller OCT provides complementary structural and functional information on biological samples and reveal that polarization contrast is more sensitive to thermal degeneration of biological tissue than amplitude-based contrast. Thus, Mueller OCT has significant potential for application in the noninvasive assessment of burn depth.
منابع مشابه
Time-domain Polarization-sensitive Optical Coherence Tomography in Soft Biological Tissue
Time-Domain Polarization-Sensitive Optical Coherence Tomography in Soft Biological Tissue. (August 2008) Milos Todorovic, B.S., University of Belgrade; M.S., Texas A&M University Co-Chairs of Advisory Committee, Dr. Lihong V. Wang Dr. Gerard L. Cote A new, high-speed, fiber-based Mueller-matrix optical coherence tomography system with continuous source-polarization modulation is presented. For ...
متن کاملIn vivo burn imaging using Mueller optical coherence tomography.
We report on the use of a high-speed, fiber-based Mueller-matrix optical coherence tomography system with continuous source-polarization modulation for in vivo burn depth evaluation and healing monitoring. A homemade hand-held probe with integrated optical scanning and beam delivering optics was coupled in the sample arm. In vivo burn imaging was demonstrated on porcine skin at different stages...
متن کاملTwo-dimensional depth-resolved Mueller matrix of biological tissue measured with double-beam polarization-sensitive optical coherence tomography.
A double-beam polarization-sensitive system based on optical coherence tomography was built to measure the Mueller matrix of scattering biological tissue with high spatial resolution. The Jones matrix of a sample can be determined with a single scan and subsequently converted into an equivalent nondepolarizing Mueller matrix. As a result, the system can be used to measure the Mueller matrix of ...
متن کاملFiber-based polarization-sensitive Mueller matrix optical coherence tomography with continuous source polarization modulation.
We report on a new configuration of fiber-based polarization-sensitive Mueller matrix optical coherence tomography that permits the acquisition of the round-trip Jones matrix of a biological sample using only one light source and a single depth scan. In this new configuration, a polarization modulator is used in the source arm to continuously modulate the incident polarization state for both th...
متن کاملPolarization contrast imaging of biological tissues by polarization-sensitive Fourier-domain optical coherence tomography.
Jones matrix imaging of biological samples by a polarization-sensitive Fourier-domain optical coherence tomography has been demonstrated using a two-dimensional CCD camera to obtain two spectra corresponding to the orthogonal polarization components simultaneously. The measurement results of a quarter-wave plate are compared between the two incident polarization sets, H-V linear and R-L circula...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Applied optics
دوره 42 25 شماره
صفحات -
تاریخ انتشار 2003