Stand-alone anterior lumbar interbody fusion – complications and perioperative results☆

نویسندگان

  • Rodrigo Amaral
  • Ronaldo Ferreira
  • Luis Marchi
  • Rubens Jensen
  • Joes Nogueira-Neto
  • Luiz Pimenta
چکیده

OBJECTIVES Historically, anterior lumbar interbody fusion (ALIF) was related to high rates of intraoperative complications and adverse events related to interbody devices. In recent decades, there have been technical adjustments, and cages that are more suitable have emerged. The aim of this study is to evaluate the efficacy and complication rate of the use of stand-alone mini-ALIF using a self-locking cage. METHODS Retrospective single center study. Inclusion criteria: retroperitoneal mini-ALIF for single-level fusion (L5S1); self-locking cage; DDD/stenosis and grade I spondylolisthesis. Exclusion criteria: posterior supplementation, previous fusion/arthroplasty. Endpoints: surgery data, intraoperative and perioperative adverse events related both to surgical access and to the intersomatic device. RESULTS Eighty-seven cases were enrolled. Median surgical time was 90 min; median blood loss was 100 mL. The median length of stay in the ICU was zero days; median hospital stay was one day. Ten cases had an adverse event (11.5%): four major adverse events (4.6%; 3 L bleeding; DVT; retroperitoneal haematoma; incisional hernia), and seven minor events (8%; peritoneum injury; minor vascular injury; events related to the cage). No cases of retrograde ejaculation were observed. There was improvement in pain, physical restriction, and quality of life (p < 0.001). CONCLUSIONS The mini-ALIF procedure performed for single-level fusion at the distal lumbar level demonstrated low adverse event rates related to both the surgical approach and to the intersomatic device, with reduced hospital stay and satisfactory perioperative clinical results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stability After Anterior Lumbar Fusion with Interbody Cages: A Radiostereometric Evaluation

Background: Interbody cage stabilization as a stand-alone procedure in lumbar spine fusion is questioned due to inconsistent mechanical effects registered in human cadaveric studies. Even segmental mobility exceeding the normal range of motion is described after cage implantation. For the anterior interbody cage fusion, this potential, undesired destabilization is explained by the resection of ...

متن کامل

Applying the Mini-Open Anterolateral Lumbar Interbody Fusion with Self-Anchored Stand-Alone Polyetheretherketone Cage in Lumbar Revision Surgery

The author retrospectively studied twenty-two patients who underwent revision lumbar surgeries using ALLIF with a self-anchored stand-alone polyetheretherketone (PEEK) cage. The operation time, blood loss, and perioperative complications were evaluated. Oswestry disability index (ODI) scores and visual analog scale (VAS) scores of leg and back pain were analyzed preoperatively and at each time ...

متن کامل

Mid-term Clinical Outcomes of Stand-alone Posterior Interbody Fusion with Rectangular Cages: A 4-year-minimum Follow-up

OBJECTIVE We sought to determine minimum 4 years of clinical outcomes including fusion rate, revision rate and complications of patients who underwent placement of rectangular stand-alone cages. METHODS Thirty-three cases of degenerative spine that had been followed for at least 4-years were reviewed retrospectively. Cages were inserted at L4-L5 level or L5-S1 in 27 or in 6 cases respectively...

متن کامل

Prospective Randomized Controlled Trial of The Stabilis Stand Alone Cage (SAC) Versus Bagby and Kuslich (BAK) Implants for Anterior Lumbar Interbody Fusion

BACKGROUND Degenerative disc disease is common and debilitating for many patients. If conservative extensive care fails, anterior lumbar interbody fusion has proven to be an alternative form of surgical management. The Stabilis Stand Alone Cage(SAC) was introduced as a method to obtain stability and fusion. The purpose of this study was to determine whether the Stabilis Stand Alone Cage (SAC) i...

متن کامل

Revisiting Anterior Stand-Alone Fixation (ASAF) Devices for the Treatment of Single Level Lumbosacral Degenerative Disease

locking screw technology, which significantly augments the overall construct strength and rigidity. The goal of the anterior stabilized stand-alone device is to negate the need for posterior fixation by promoting stability of the implant via the locking screws. The benefit of creating an anterior stand-alone fixation device is that the spine surgeon can achieve adequate stabilization to ensure ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 52  شماره 

صفحات  -

تاریخ انتشار 2017