Impact of peri-stent remodeling on restenosis: a volumetric intravascular ultrasound study.
نویسندگان
چکیده
BACKGROUND Vessel remodeling is an important mechanism of late lumen loss after nonstent coronary interventions. However, its impact on in-stent restenosis has not been systematically investigated. METHODS AND RESULTS Serial volumetric intravascular ultrasound analyses (poststent and follow-up) were performed in 55 lesions treated with a balloon-expandable stent (ACS MultiLink) using standard stent deployment techniques. The vessel volume (VV), lumen volume (LV), and volume bordered by the stent (SV) were measured using Simpson's method. The volume of plaque and neointima outside the stent (peri-stent volume, PSV) and volume of neointima within the stent (intrastent volume) were also measured. The change of each parameter during the follow-up period (follow-up minus poststent) was calculated and then divided by SV to normalize these values (designated as percent change [%]). As expected, %PSV directly correlated with %VV (P<0.0001, r=0.935), with no significant SV. A highly significant inverse correlation was seen between %PSV and the percent change of intrastent volume (P<0.0001, r=0.517). Consequently, %LV significantly correlated with peri-stent remodeling, as measured by %VV (P<0.0001, r=0.602). CONCLUSION Positive remodeling of the vessel exterior to a coronary stent occurs to a variable degree after stent implantation. There is a distinct trade-off between positive remodeling and in-stent hyperplasia: in segments in which the degree of peri-stent remodeling is less, intrastent neointimal proliferation is greater and accompanied by more significant late lumen loss.
منابع مشابه
Arterial remodeling patterns before intervention predict diffuse in-stent restenosis: an intravascular ultrasound study.
OBJECTIVES The aim of this retrospective study was to determine the predictors of diffuse in-stent restenosis (ISR) among the lesions causing the first ISR by intravascular ultrasound (IVUS) studies. BACKGROUND Although some predictors of diffuse ISR have been reported, parameters on IVUS relating to diffuse ISR are not well characterized. METHODS We classified 52 ISR lesions that had under...
متن کاملSmall stent size and intimal hyperplasia contribute to restenosis: a volumetric intravascular ultrasound analysis.
OBJECTIVES The purpose of this study was to use volumetric intravascular ultrasound analysis of Palmaz-Schatz stents to assess the in-stent restenotic process. BACKGROUND By reducing lesion elastic recoil and chronic arterial remodeling, stents improve the long-term results of coronary angioplasty. However, stents are prone to the development of neointimal hyperplasia. Angiographic studies of...
متن کاملDoes a well developed collateral circulation predispose to restenosis after percutaneous coronary intervention? An intravascular ultrasound study.
OBJECTIVE To evaluate whether a well developed collateral circulation predisposes to restenosis after percutaneous coronary intervention (PCI). DESIGN Prospective observational study. PATIENTS AND SETTING 58 patients undergoing elective single vessel PCI in a tertiary referral interventional cardiac unit in the UK. METHODS Collateral flow index (CFI) was calculated as (Pw-Pv)/(Pa-Pv), whe...
متن کاملUsual Dose of Simvastatin Does Not Inhibit Plaque Progression and Lumen Loss at the Peri-Stent Reference Segments after Bare-Metal Stent Implantation: A Serial Intravascular Ultrasound Analysis
BACKGROUND/AIMS The aim of this study was to assess the effects of a usual dose of simvastatin (20 mg/day) on plaque regression and vascular remodeling at the peri-stent reference segments after bare-metal stent implantation. METHODS We retrospectively investigated serial intravascular ultrasound (IVUS) findings in 380 peri-stent reference segments (184 proximal and 196 distal to the stent) i...
متن کاملLate and very late drug-eluting stent malapposition: serial 2-year quantitative IVUS analysis.
BACKGROUND The long-term natural history of acquired malapposition continues to be the subject of debate. METHODS AND RESULTS Using volumetric intravascular ultrasound analyses, we evaluated serial (poststenting, 6-month, and 2-year follow-up) changes in drug-eluting stent-treated vascular segments with acquired malapposition. External elastic membrane, stent, lumen, malapposition, and perist...