Comparison of CT and MRI for diagnosis of suspected scaphoid fractures.

نویسندگان

  • Wouter Mallee
  • Job N Doornberg
  • David Ring
  • C Niek van Dijk
  • Mario Maas
  • J Carel Goslings
چکیده

BACKGROUND There is no consensus on the optimum imaging method to use to confirm the diagnosis of true scaphoid fractures among patients with suspected scaphoid fractures. This study tested the null hypothesis that computed tomography (CT) and magnetic resonance imaging (MRI) have the same diagnostic performance characteristics for the diagnosis of scaphoid fractures. METHODS Thirty-four consecutive patients with a suspected scaphoid fracture (tenderness of the scaphoid and normal radiographic findings after a fall on the outstretched hand) underwent CT and MRI within ten days after a wrist injury. The reference standard for a true fracture of the scaphoid was six-week follow-up radiographs in four views. A panel including surgeons and radiologists came to a consensus diagnosis for each type of imaging. The images were considered in a randomly ordered, blinded fashion, independent of the other types of imaging. We calculated sensitivity, specificity, and accuracy as well as positive and negative predictive values. RESULTS The reference standard revealed six true fractures of the scaphoid (prevalence, 18%). CT demonstrated a fracture in five patients (15%), with one false-positive, two false-negative, and four true-positive results. MRI demonstrated a fracture in seven patients (21%), with three false-positive, two false-negative, and four true-positive results. The sensitivity, specificity, and accuracy were 67%, 96%, and 91%, respectively, for CT and 67%, 89%, and 85%, respectively, for MRI. According to the McNemar test for paired binary data, these differences were not significant. The positive predictive value with use of the Bayes formula was 0.76 for CT and 0.54 for MRI. The negative predictive value was 0.94 for CT and 0.93 for MRI. CONCLUSIONS CT and MRI had comparable diagnostic characteristics. Both were better at excluding scaphoid fractures than they were at confirming them, and both were subject to false-positive and false-negative interpretations. The best reference standard is debatable, but it is now unclear whether or not bone edema on MRI and small unicortical lines on CT represent a true fracture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cost-Effectiveness of Diagnostic Strategies for Suspected Scaphoid Fractures.

OBJECTIVES The aim of this study was to assess the cost effectiveness of multiple competing diagnostic strategies for suspected scaphoid fractures. METHODS With published data, the authors created a decision-tree model simulating the diagnosis of suspected scaphoid fractures. Clinical outcomes, costs, and cost effectiveness of immediate computed tomography (CT), day 3 magnetic resonance imagi...

متن کامل

Inter-observer agreement between 2-dimensional CT versus 3-dimensional I-Space model in the Diagnosis of Occult Scaphoid Fractures

  Background: The I-Space is a radiological imaging system in which Computed Tomography (CT)-scans can be evaluated as a three dimensional hologram. The aim of this study is to analyze the value of virtual reality (I-Space) in diagnosing acute occult scaphoid fractures.   Methods: A convenient cohort of 24 patients with a CT-scan from prior studies, without a scaphoid fracture on radiograph, ye...

متن کامل

Diagnosing suspected scaphoid fractures: a systematic review and meta-analysis.

UNLABELLED Imaging protocols for suspected scaphoid fractures among investigators and hospitals are markedly inconsistent. We performed a systematic review and meta-analysis to assess and compare the diagnostic performance of bone scintigraphy, MRI, and CT for diagnosing suspected scaphoid fractures. Twenty-six studies were included. Sensitivity, specificity, and diagnostic odds ratio were pool...

متن کامل

Diagnosis of Occult Scaphoid Fractures: A Cost-Effectiveness Analysis.

BACKGROUND Scaphoid fractures are common but may be missed on initial radiographs. Advanced imaging modalities such as computed tomography (CT) and magnetic resonance imaging (MRI) have improved diagnostic accuracy, but at an increased initial cost. The purpose of this study was to evaluate the cost-effectiveness of immediate advanced imaging for suspected occult scaphoid fractures. METHODS A...

متن کامل

Early magnetic resonance imaging compared with bone scintigraphy in suspected scaphoid fractures.

We evaluated 100 consecutive patients with a suspected scaphoid fracture but without evidence of a fracture on plain radiographs using MRI within 24 hours of injury, and bone scintigraphy three to five days after injury. The reference standard for a true radiologically-occult scaphoid fracture was either a diagnosis of fracture on both MRI and bone scintigraphy, or, in the case of discrepancy, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. American volume

دوره 93 1  شماره 

صفحات  -

تاریخ انتشار 2011