Estimation of absolute myocardial blood flow during first-pass MR perfusion imaging using a dual-bolus injection technique: comparison to single-bolus injection method.
نویسندگان
چکیده
PURPOSE To compare the dual-bolus to single-bolus quantitative first-pass magnetic resonance myocardial perfusion imaging for estimation of absolute myocardial blood flow (MBF). MATERIALS AND METHODS Dogs had local hyperemia of MBF in the left anterior descending (LAD) coronary artery (intracoronary adenosine). Animals (n = 6) had sequential single- and dual-bolus perfusion studies with microsphere determination of absolute MBF. Perfusion imaging was performed using a saturation-recovery gradient-echo sequence. Absolute MBF was by Fermi function deconvolution and compared to transmural, endocardial, and epicardial microsphere values in the same region of interest (ROI). RESULTS Signal and contrast were significantly higher for the dual-bolus perfusion images. The correlation with MBF by microspheres was r = 0.94 for the dual-bolus method and r = 0.91 for the single-bolus method. There was no significant difference between MRI and microsphere MBF values for control or hyperemic zones for transmural segments for either technique. When the ROI was reduced to define endocardial and epicardial zones, single-bolus MR first-pass imaging significantly overestimated MBF and had a significantly larger absolute error vs. microspheres when compared to dual-bolus perfusion. CONCLUSION Both single-bolus and dual-bolus perfusion methods correlate closely with MBF but the signal and contrast of the dual-bolus images are greater. With smaller nontransmural ROIs where signal is reduced, the dual-bolus method appeared to provide slightly more accurate results.
منابع مشابه
Comparison of dual to single contrast bolus magnetic resonance myocardial perfusion imaging for detection of significant coronary artery disease.
PURPOSE To investigate the incremental diagnostic value of dual-bolus over single-contrast-bolus first pass magnetic resonance myocardial perfusion imaging (MR-MPI) for detection of significant coronary artery disease (CAD). MATERIALS AND METHODS Patients (n = 49) with suspected CAD underwent first pass adenosine stress and rest MR-MPI and invasive coronary angiography (CA). Gadolinium diethy...
متن کاملQuantitative Myocardial Perfusion Using Conventional Single-Bolus Contrast Imaging Overestimates Absolute Myocardial Blood Flow Compared with Dual-Bolus or Dual-Sequence Cardiac MR Methods
Introduction: Estimates of myocardial blood flow (MBF) from first-pass contrast-enhanced cardiac magnetic resonance (CMR) imaging require accurate measurement of the arterial input function (AIF) from the left-ventricular (LV) blood pool. Both dual-bolus [1] and dual-sequence [2,3] CMR methods have been proposed to maintain the linearity of the LV signal during the contrast passage. Several stu...
متن کاملComparison of single to dual bolus MR myocardial perfusion imaging for detection of coronary artery disease
Introduction Absolute myocardial perfusion can be determined using first pass MR myocardial perfusion imaging with a Fermi-model constrained deconvolution [1]. In the analysis, a linear relationship between contrast concentration and signal intensity is mostly assumed. However, at high contrast concentration saturation effects cause a non linear effect. As low contrast concentrations limits the...
متن کاملA comparison of dual-bolus and dual-sequence quantitative myocardial perfusion techniques
Background Single bolus quantitative myocardial perfusion is sensitive to systematic errors due to the non-linear relationship between contrast agent concentration and MR signal. These errors can be minimised by using a low dose contrast bolus or by altering the imaging sequence parameters. However, these approaches substantially reduce the contrast to noise ratio of the images increasing the n...
متن کاملMeasurement of myocardial blood flow by cardiovascular magnetic resonance perfusion: comparison of distributed parameter and Fermi models with single and dual bolus
BACKGROUND Mathematical modeling of cardiovascular magnetic resonance perfusion data allows absolute quantification of myocardial blood flow. Saturation of left ventricle signal during standard contrast administration can compromise the input function used when applying these models. This saturation effect is evident during application of standard Fermi models in single bolus perfusion data. Du...