[Intensity-modulation radiotherapy using independent collimator: algorithm study].
نویسندگان
چکیده
To investigate algorithms for independent collimator (IC) to modulate beam intensity distributions. Field-setting sequences were determined for three clinical intensity distributions with two forward algorithms. The delivery order of all fields in the sequences was optimized in order to minimize the overall jaw-moving time. Suppose treatments were performed with Varian 600C, delivery time was calculated. The delivery time was between 5 min to 10 min, It was approximately inversely proportional to machine dose rate, and also related to algorithm, number of intensity levels and metrix element size.
منابع مشابه
The generation of intensity-modulated fields for conformal radiotherapy by dynamic collimation
An algorithm has been developed to calculate the collimator jaw motions required to generate intensity-modulated fields far use in conformal radiotherapy. The dynamic technique allows arbitrary intensity profiles to he generated using a single unidirectional sweep of the collimators. The collimator jaws have independent motion, so that an aperture of variable width is scanned across the field. ...
متن کاملStatic and dynamic beam intensity modulation in radiotherapy using a multileaf collimator
Cover: Generation of an intensity modulated field by using dynamic multileaf collimation.
متن کاملComparison of RapidArc and Static Gantry Intensity-modulated Radiotherapy for Nasopharyngeal Carcinoma
Objective: RapidArc (Varian Medical Systems, Palo Alto, CA) is a new volumetric-modulated arc radiotherapy technique with continuous modulation of gantry speed, dose rate, and multileaf collimator shape. Taking advantages of dose painting capabilities along with rotational delivery, RapidArc has shown promise in the treatment of a wide range of tumours, including intracranial, head and neck, pr...
متن کاملOptimal Sequencing of Dynamic Multileaf Collimators
Dynamic multileaf collimator (DMLC)-intensity modulated radiation therapy (IMRT) is used to delivery intensity-modulated beams using an MLC, with the leaves in motion. DMLC-IMRT requires the conversion of a radiation fluence map into a leaf sequence file that controls the movement of the MLC while the beam is on. It is imperative that the fluence map delivered using the leaf sequence file be as...
متن کاملA new mathematical model for intensity matrix decomposition using multileaf collimator
Cancer is one of the major causes of death all over the globe and radiotherapy is considered one of its most effective treatment methods. Designing a radiotherapy treatment plan was done entirely manually in the past. RecentlyIntensity Modulated Radiation Therapy (IMRT) was introduced as a new technology with advanced medical equipmentin the recent years. IMRT provides the opportunity to delive...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 26 12 شماره
صفحات -
تاریخ انتشار 1999