An in vitro study of cartilage-meniscus tribology to understand the changes caused by a meniscus implant.
نویسندگان
چکیده
Active lifestyles increase the risk of meniscal injury. A permanent meniscus implant of polycarbonate urethane (PCU) is a promising treatment to postpone/prevent total knee arthroplasty. Study of the changes in articular cartilage tribology in the presence of PCU is essential in developing the optimum meniscus implant. Therefore, a cartilage-meniscus reciprocating, sliding model was developed in vitro, mimicking the stance and swing phases of the gait cycle. The meniscus was further replaced with PCU and surface-modified PCUs (with C18 chains, mono-functional polydimethylsiloxane groups and mono-functional polytetrafluoroethylene groups) to study the changes. The coefficient of friction (COF) was calculated, and cartilage wear was determined and quantified histologically. The cartilage-meniscus sliding resulted in low COF during both stance and swing (0.01< COF <0.12) and low wear of cartilage (scores <1). The cartilage-PCU sliding, during stance, revealed similar low COFs. But during swing, the COFs were high (average ∼1, maximum 1.6), indicating a breakdown in interstitial fluid pressurization lubrication and non-effective activation of the boundary lubrication. This may lead to wear of cartilage in long term. However, under the tested conditions the wear of cartilage against PCUs was not higher than its wear against meniscus, and the cartilage was occasionally damaged. The COF decreased with increasing the contact pressure (as-per a power equation) up to 1MPa. The changes in the surface modification of PCU did not affect PCU's tribological performance.
منابع مشابه
Save the Meniscus, A Good Strategy to Preserve the Knee
With increasing life expectancy, the demand for preservation of native articular cartilage is increasing to delay joint arthroplasties. In the knee, there are many different strategies to preserve the articular cartilage including but not limited to corrective osteotomies, chondral injury restoration, intraarticular injection of cells or growth factors(PRP). However, One of the most important s...
متن کاملEffect on tissue differentiation and articular cartilage degradation of a polymer meniscus implant: A 2-year follow-up study in dogs.
BACKGROUND Replacement of the meniscus by an implant could potentially avoid cartilage degeneration. HYPOTHESIS An implant of degradable polycaprolacton-polyurethane should act as a temporary scaffold enabling regeneration of a new meniscus by slow degradation of the polymer and simultaneous in-growth and differentiation of tissues into the typical cartilage-like tissue of the meniscus. STU...
متن کاملThe sensitivity of cartilage contact pressures in the knee joint to the size and shape of an anatomically shaped meniscal implant.
Since meniscal geometry affects the cartilage contact pressures, it is essential to carefully define the geometry of the synthetic meniscal implant that we developed. Recently, six independent modes of size- and shape-related geometry variation were identified through 3D statistical shape modeling (SSM) of the medial meniscus. However, this model did not provide information on the functional im...
متن کاملReplacement of the knee meniscus by a porous polymer implant: a study in dogs.
BACKGROUND Meniscectomy will lead to articular cartilage degeneration in the long term. Therefore, the authors developed an implant to replace the native meniscus. HYPOTHESIS The porous polymer meniscus implant develops into a neomeniscus and protects the cartilage from degeneration. STUDY DESIGN Controlled laboratory study. METHODS In a dog model, a porous polymer scaffold with optimal p...
متن کاملFriction properties of a new silk fibroin scaffold for meniscal replacement
The menisci protect the articular cartilage by reducing contact pressure in the knee. To restore their function after injury, a new silk fibroin replacement scaffold was developed. To elucidate its tribological properties, friction of the implant was tested against cartilage and glass, where the latter is typically used in tribological cartilage studies. The silk scaffold exhibited a friction c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Colloids and surfaces. B, Biointerfaces
دوره 155 شماره
صفحات -
تاریخ انتشار 2017