Prediction of Primary Slow-Pathway Ablation Success Rate according to the Characteristics of Junctional Rhythm Developed during the Radiofrequency Catheter Ablation of Atrioventricular Nodal Reentrant Tachycardia

نویسندگان

  • Ataallah Bagherzadeh
  • Mohammad Esmaeel Rezaee
  • Maryam Moshkani Farahani
چکیده

BACKGROUND Nowadays, developed junctional rhythm (JR) that occurs during slow-pathway radiofrequency (RF) catheter ablation of atrioventricular nodal reentrant tachycardia (AVNRT) has been focused upon as a highly sensitive surrogate end point for successful radiofrequency ablation. This study was conducted to assess the relationship between the presence and pattern of developed JR during the RF ablation of AVNRT and a successful outcome. METHODS Seventy-five patients aged between 14 and 88 who underwent slow-pathway RF ablation due to symptomatic AVNRT were enrolled into the study and received a total of 162 RF energy applications. Combined anatomic and electrogram mapping approach was used for slow-pathway RF ablation. The ablation procedure consisted of 60-second, 60 °C temperature-controlled energy delivery. After each ablation pulse, successful ablation was assessed according to the loss of AVNRT inducibility via isoproterenol infusion. Four different patterns were considered for the developed JR, namely sparse, intermittent, continuous, and transient block. Success ablation rate was assessed with respect to the position, pattern, and number of junctional beats. RESULTS Successful RF ablation with a loss of AVNRT inducibility was achieved in 43 (57.3%) patients using 119 RF energy applications (73.5%). JR developed in 133 of the 162 (82.1%) applications with a given sensitivity of 90.8% and low specificity of 41.9% as an end point of successful RF ablation, with a negative predictive value of 62.1%. The mean number of the developed junctional beats was significantly higher in the successful ablations (p value < 0.001), and the ROC analysis revealed that the best cut-off point of the cumulative junctional beats for identifying accurate AVNRT ablation therapy is 14 beats with 90.76 % sensitivity and 90.70% specificity. There were no significant differences in terms of successful ablation rates according to the four different patterns of JR and its positions (p value=0.338, p value=0.105, respectively) in the univariate analyses. CONCLUSION JR is a sensitive but non-specific predictor of the successful RF ablation of AVNRT. Nevertheless, according to the results, its specificity could increase with the presence of more than 14 cumulative junctional beats. Although the development of JR during slow-pathway RF ablation seems not to be reliable as a success end point, its absences could be a marker of requiring more energy application to ablate the slow pathway.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Absence of junctional rhythm during successful slow-pathway ablation in patients with atrioventricular nodal reentrant tachycardia.

BACKGROUND The presence of junctional rhythm has been considered to be a sensitive marker of successful slow-pathway ablation. However, in rare cases, junctional rhythm was absent despite multiple radiofrequency applications delivered over a large area in the Koch's triangle, and successful ablation was achieved in the absence of a junctional rhythm. METHODS AND RESULTS This study included 35...

متن کامل

Atrioventricular nodal reentrant tachycardia ablation with radiofrequency energy during ongoing tachycardia: is it feasible?

INTRODUCTION Radiofrequency (RF) ablation of the slow pathway for treatment of atrioventricular nodal reentrant tachycardia (AVNRT) is conventionally performed during sinus rhythm. AIM To evaluate the clinical and electrophysiological features and the short- and long-term results of slow pathway RF ablation during ongoing AVNRT. MATERIAL AND METHODS A total of 282 consecutive patients with ...

متن کامل

مقایسه قطع کردن کامل در مقایسه با ناقص مسیر کوتاه در بیماران مبتلا به تاکی کاردی بازگشت گره ی دهلیزی-بطنی از نظر عود علایم و عوارض

Background and purpose: Catheter radiofrequency ablation is the first step in therapeutic approach to Atrioventricular nodal reentrant tachycardia (AVNRT). Different protocols for slow pathway ablation are found to have various ranges of efficacy and side effects. This study compared the effects of partial and complete ablation of the slow pathway on recurrence, symptom relief and complications...

متن کامل

Radiofrequency catheter ablation of atypical atrioventricular nodal reentrant tachycardia.

INTRODUCTION Published reports of radiofrequency ablation of atypical atrioventricular nodal reentrant tachycardia (AVNRT) have been limited. We present our experience in 10 consecutive patients with atypical AVNRT who underwent radiofrequency ablation of the "slow" AV nodal pathway. METHODS AND RESULTS There were 9 females and 1 male; their mean age was 44 +/- 19 years (+/- SD). The mean AVN...

متن کامل

Temperature-controlled slow pathway ablation for treatment of atrioventricular nodal reentrant tachycardia using a combined anatomical and electrogram guided strategy.

AIMS Anatomical and electrogram-guided techniques have been used separately for slow pathway ablation in atrioventricular nodal reentrant tachycardia. The aims of the present study were to analyse electrogram characteristics of target sites and biophysical parameters using a combined anatomical and electrogram-guided technique for temperature-controlled radiofrequency catheter ablation of the s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2011