Knowledge of electrical tissue conductivity is necessary to determine deposition of electromagnetic energy and can further be used to diagnostically differentiate between normal and neoplastic tissue. We measured 17 rats with a total of 24 tumours of the K12/TRb rat colon cancer cell line. In each animal we measured in vivo hepatic tumour and normal tissue conductivity at seven frequencies from 10 Hz to 1 MHz, at different tumour stages between 6 and 12 weeks after induction. Conductivity of normal liver tissue was 1.26 +/- 0.15 mS cm(-1) at 10 Hz, and 4.61 +/- 0.42 mS cm(-1) at 1 MHz. Conductivity of tumour was 2.69 +/- 0.91 mS cm(-1) at 10 Hz, and 5.23 +/- 0.82 mS cm(-1) at 1 MHz. Conductivity was significantly different between normal and tumour tissue (p < 0.05). We determined the percentage of necrosis and fibrosis at the measurement site. We fitted the conductivity data to the Cole-Cole model. For the tumour data we determined Spearman's correlation coefficients between the Cole-Cole parameters and age, necrosis, fibrosis and tumour volume and found significant correlation between necrosis and the Cole-Cole parameters (p < 0.05). We conclude that necrosis within the tumour and the associated membrane breakdown is likely responsible for the observed change in conductivity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrical conductivity measurement of excised human metastatic liver tumours before and after thermal ablation.

We measured the ex vivo electrical conductivity of eight human metastatic liver tumours and six normal liver tissue samples from six patients using the four electrode method over the frequency range 10 Hz to 1 MHz. In addition, in a single patient we measured the electrical conductivity before and after the thermal ablation of normal and tumour tissue. The average conductivity of tumour tissue ...

متن کامل

Ex vivo electrical impedance measurements on excised hepatic tissue from human patients with metastatic colorectal cancer.

Point-wise ex vivo electrical impedance spectroscopy measurements were conducted on excised hepatic tissue from human patients with metastatic colorectal cancer using a linear four-electrode impedance probe. This study of 132 measurements from 10 colorectal cancer patients, the largest to date, reports that the equivalent electrical conductivity for tumor tissue is significantly higher than nor...

متن کامل

مطالعۀ خواص الکتریکی یک دزیمتر جدید بر پایۀ نانوکامپوزیت پلیمر-نانولوله کربن

Use of carbon nanotubes (CNTs) in dosimetry is a promising technique for real time in vivo dose measurements with high resolution for nuclear medicine and also dose rate monitoring for radiation protection utilizations. In this research with respect to extraordinary electrical properties of CNTs for several order of magnitudes increasing in electrical conductivity of polymeric matrix, the idea ...

متن کامل

Finite Element Analysis of Hepatic Radiofrequency Ablation Probes using Temperature-Dependent Electrical Conductivity

BACKGROUND Few finite element models (FEM) have been developed to describe the electric field, specific absorption rate (SAR), and the temperature distribution surrounding hepatic radiofrequency ablation probes. To date, a coupled finite element model that accounts for the temperature-dependent electrical conductivity changes has not been developed for ablation type devices. While it is widely ...

متن کامل

Thermal and electrical conductivity of Aluminium Nitride nanofluids

This study was designed to experimentally measure the thermal and electrical conductivities of Aluminium Nitride/Ethylene Glycol (AlN/EG) nanofluids. Transmission electron microscopy (TEM) was used to characterize the shape of AlN nanoparticles. Nanofluids with different particle volume concentrations of 0.5%, 1%, 2%, 3%, 4%, and 5% were utilized. The thermal and electrical conductivities of the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological measurement

دوره 24 2  شماره 

صفحات  -

تاریخ انتشار 2003