Minimum 5-year follow-up for primary THA using a tapered, proximally coated cementless stem.

نویسندگان

  • Frank R Kolisek
  • Kimona Issa
  • Steven F Harwin
  • Charles Jaggard
  • Qais Naziri
  • Michael A Mont
چکیده

The purpose of this study was to assess the survivorship of a proximally coated, cementless femoral stem used for total hip arthroplasty at a minimum 5-year follow-up by assessing clinical outcomes and implant survival. A total of 936 primary total hip arthroplasties were performed in 854 patients by 3 high-volume surgeons between 2001 and 2007. Patients included 385 men and 469 women with a mean age of 56 years (range, 20-88 years) and a mean follow-up of 7 years (range, 5-11 years). The aseptic revision rate related to the femoral component was 0.3%. Three patients underwent revision of the femoral component. Mean postoperative Harris Hip Score improved to 91 points (range, 70-100 points). When stratified by primary cause of total hip arthroplasty, no differences were found in implant survivorship or postoperative Harris Hip Scores. With the exception of the 3 patients who underwent revision surgery, postoperative radiographic evaluation of the stems demonstrated no progressive radiolucencies, component malalignment, change in component position, or implant subsidence at most recent follow-up.These results are encouraging and indicate a 0.3% revision rate for the femoral component. The cause of primary total hip arthroplasty did not affect the clinical outcomes. These types of prostheses will provide patients with a stable implant that is expected to have excellent durability and longevity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Four- to six-year follow-up of primary THA using contemporary titanium tapered stems.

Tapered cementless femoral components have been used in total hip arthroplasty constructs for more than 20 years. In the past 5 to 10 years, these stems have gained popularity in the United States. The purpose of this study was to evaluate the results of the authors’ initial experience using a contemporary tapered, proximally porous-coated, titanium femoral component at 4 to 6 years of follow-u...

متن کامل

Seven-year Results of a Tapered, Titanium, Hydroxyapatite-Coated Cementless Femoral Stem in Primary Total Hip Arthroplasty

BACKGROUND Aseptic loosening of cemented hip prostheses is recognized as a long-term problem, and especially in males and younger patients. Much energy has been focused on developing new prostheses that are designed for cementless fixation. We evaluated the performance of and periprosthetic bone response to a tapered, titanium, hydroxyapatite (HA)-coated femoral hip prosthesis at a minimum of 7...

متن کامل

Mid-term outcome of a modular, cementless, proximally hydroxyapatite-coated, anatomic femoral stem.

PURPOSE To report the mid-term outcome of a modular, cementless, proximally hydroxyapatitecoated, anatomic femoral stem in total hip arthroplasty (THA). METHODS 160 consecutive patients aged 42 to 92 (mean, 70) years underwent 185 cementless THAs for primary osteoarthritis or femoral neck fractures. All procedures were performed by a single surgeon using the same modular, cementless, proximal...

متن کامل

Early performance-based and patient-reported outcomes of a contemporary taper fit bone-conserving short stem femoral component in total hip arthroplasty.

AIMS The aim of this study was to compare early functional and health related quality of life outcomes (HRQoL) in patients who have undergone total hip arthroplasty (THA) using a bone conserving short stem femoral component and those in whom a conventional length uncemented component was used. Outcome was assessed using a validated performance based outcome instrument as well as patient reporte...

متن کامل

Second-Generation Versus First-Generation Cementless Tapered Wedge Femoral Stems.

Clinical outcomes of a new second-generation proximally coated, tapered wedge cementless stem were compared with those of its predecessor regarding (1) all-cause implant survivorship; (2) objective and subjective outcomes; (3) complications; and (4) radiographic features. Patients who underwent a primary total hip arthroplasty with the second-generation stem (68 hips) were compared with those w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Orthopedics

دوره 36 5  شماره 

صفحات  -

تاریخ انتشار 2013