Inappropriate ICD discharges in single-chamber versus dual-chamber devices in the pediatric and young adult population.

نویسندگان

  • David Lawrence
  • Nicholas Von Bergen
  • Ian H Law
  • David J Bradley
  • Macdonald Dick
  • Patricio A Frias
  • Margaret J Streiper
  • Peter S Fischbach
چکیده

BACKGROUND Implantable cardioverter defibrillator (ICD) use is increasing in young patients and is frequently complicated by inappropriate device discharges (IDs), leading to discomfort, anxiety and, potentially, proarrhythmia. Dual-chamber (DC) ICDs may decrease IDs by improving rhythm discrimination, but are associated with increased size, expense, and implant complications. We examined whether the frequency of IDs was the same in dual- and single-chamber (SC) ICDs in young patients. METHODS A multicenter review of patients <or=30 years of age with ICDs was performed. Demographic data and number of appropriate discharges (ADs) and IDs were collected. ADs and IDs were categorized after review of the episode by the primary electrophysiologist. RESULTS Of 168 subjects (SC = 52; female = 76), 41 patients received 139 ADs, while 35 patients received 159 IDs. There were no differences related to gender or primary diagnosis, but patients with SC versus DC devices were younger (12.3 +/- 5.0 years vs 14.9 +/- 4.4 years, P < 0.0001) at implant. SC and DC devices were implanted with the same frequency for primary and secondary prevention. There were no significant differences in the incidence of IDs or ADs between the patients with SC or DC devices (AD: 12/52 SC vs 29/116 DC, P = 0.79; ID 7/52 SC vs 28/116 DC, P = 0.13). CONCLUSION In this cohort of young patients, DC ICDs did not provide added protection from IDs. Hence, the added complexity and cost of an atrial lead appear unwarranted if used solely for assistance with rhythm discrimination in young patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inappropriate Shocks in Patients with ICDs: Single Chamber versus Dual Chamber

BACKGROUND Despite the technological evolution of the implantable defibrillator, one of the questions that remains is the possible benefit of the dual chamber versus single chamber implantable cardioverter defibrillator (ICD) in reducing inappropriate shocks. OBJECTIVE To evaluate which type of device provides fewer inappropriate shocks (dual chamber versus single chamber) in patients with im...

متن کامل

Comparison of Inappropriate Shocks and Other Health Outcomes Between Single‐ and Dual‐Chamber Implantable Cardioverter‐Defibrillators for Primary Prevention of Sudden Cardiac Death: Results From the Cardiovascular Research Network Longitudinal Study of Implantable Cardioverter‐Defibrillators

BACKGROUND In US clinical practice, many patients who undergo placement of an implantable cardioverter-defibrillator (ICD) for primary prevention of sudden cardiac death receive dual-chamber devices. The superiority of dual-chamber over single-chamber devices in reducing the risk of inappropriate ICD shocks in clinical practice has not been established. The objective of this study was to compar...

متن کامل

Inappropriate cardioverter-defibrillator discharge continues to be a major problem in clinical practice.

BACKGROUND The purpose of this study was to determine the rate and causes of inappropriate rhythm detection, and to compare adequacy of ventricular arrhythmia detection by single-chamber and dual-chamber cardioverter-defibrillators (ICD). METHODS We evaluated 190 patients (age 57.2 +/- 11.2 years) with ICD. FOLLOW-UP 34.3 +/- +/- 22 months. Dual-chamber ICD was used in 54 patients. RESULT...

متن کامل

Dual-chamber versus single-chamber detection enhancements for implantable defibrillator rhythm diagnosis: the detect supraventricular tachycardia study.

BACKGROUND Delivery of inappropriate shocks caused by misdetection of supraventricular tachycardia (SVT) remains a substantial complication of implanted cardioverter/defibrillator (ICD) therapy. Whether use of optimally programmed dual-chamber ICDs lowers this risk compared with that in single-chamber ICDs is not clear. METHODS AND RESULTS Subjects with a clinical indication for ICD (n=400) a...

متن کامل

Reduced risk for inappropriate implantable cardioverter-defibrillator shocks with dual-chamber therapy compared with single-chamber therapy: results of the randomized OPTION study.

OBJECTIVES The OPTION (Optimal Anti-Tachycardia Therapy in Implantable Cardioverter-Defibrillator Patients Without Pacing Indications) trial sought to compare long-term rates of inappropriate shocks, mortality, and morbidity between dual-chamber and single-chamber settings in implantable cardioverter-defibrillators (ICDs) patients. BACKGROUND The use of dual-chamber ICDs potentially allows be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiovascular electrophysiology

دوره 20 3  شماره 

صفحات  -

تاریخ انتشار 2009