Clinical evaluation of breast dose and the factors affecting breast dose in screen-film mammography.

نویسنده

  • Ayşegül Ozdemir
چکیده

PURPOSE To investigate the factors affecting the mammographic breast dose. MATERIALS AND METHODS The assessment was done on 622 qualified mammograms obtained with use of "variable kV" technique, i. e., semiautomatic mode, in screen-film mammography. Actual breast doses were calculated and analyzed to determine the roles of two screens and three films, two anode/filter selections (Mo/Mo and Mo/ Rh), three imaging projections (craniocaudal, 45 degrees and 60 degrees mediolateral oblique [MLO]), breast thickness, and breast composition. RESULTS Min R 2190 screen provided about half dose of Min R screen. All films used with the faster screen resulted in similar doses in < 50 mm thicknesses (mean, 0.9-1.1 mGy) (P > 0.05). The doses were significantly greater in thicker (> or =50 mm) breasts, in dense breasts, and in 45 degrees MLO view, compared to the < 50 mm breasts, fatty breasts and in 60 degrees view (P < 0.05). CONCLUSION The affecting factors of dose are many, and their complex interrelations are difficult to control in clinical settings. Well tailoring of kVp/anode/filter combination, selection of faster screens and well matched films are mandatory, while 60 degrees instead of 45 degrees in oblique projection can help reducing the dose. However, tailoring of kVp/anode/filter, which should be based on both breast thickness and composition, is difficult to achieve accurately at all times. Therefore, automatic beam quality control should replace the semiautomatic mode in screen-film mammography practice in order to provide easier and more effective control on breast dose and image quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of Mean Estimation of Mean Glandular Dose in Mammography Examination in some of Radiology Centers in Tehran city

Introduction: the objectives of this research were determination of Mean Glandular Dose in film- screen and digital mammography examinations, estimation of accumulated effective dose in some of mammography centers in Tehran city and estimating cancer risk due to these examinations. Materials and Methods: the clinical data were collected from the 1318 <...

متن کامل

Comparison Between Film-Screen and Digital Mammography for Woman Breast Cancer Screening: Mean Glandular Dose

Introduction: Most studies in mammography have only been carried out in a comparison of image quality and lesion detection in film-screen mammography (FSM) and full field digital mammography (FFDM) systems. The aim of this paper was to evaluate mean glandular dose (MGD) of patient and affecting factors by FSM and FFDM to estimate which one gives a brief radiation protection to patient. Material...

متن کامل

Designing a shield to reduce radiation dose during mammography: Dosimetric evaluation

Background: This paper presents a method to reduce radiation exposure during mammography by analysing the doses to ipsilateral and contralateral breasts and to adjacent organs by evaluating material-dependent shielding performance.  Materials and Methods: Six target-filter combinations (Mo-Mo, Mo-Rh, Rh-Rh, Rh-Mo, W-Mo, W-Rh) were tested by measuring the doses delivered to the breasts and adjac...

متن کامل

Evaluation of glandular dose in mammography in the presence of breast cyst using Monte Carlo simulation

Introduction: Average glandular dose (AGD), entrance skin air kerma (ESAK) and normalized glandular dose (DgN) are the main dosimetric quantities in mammography. In this study, DgN is evaluated in the presence of breast cyst, which is a common disease among women and the influence of size, number and location of the cysts on the DgN is investigated. Materials and Meth...

متن کامل

Breast dose in conventional and digital mamography

Introduction: The amount of doses received in mammography is one of the biggest concerns in the world. According to some statistics, every 12 minutes a woman dies due to breast cancer. Mammography concerned to detect breast cancer at an early stage of the disease as well as for screening, however due to the risk of exposure, the increasingly and widespread use of mammography fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diagnostic and interventional radiology

دوره 13 3  شماره 

صفحات  -

تاریخ انتشار 2007