A new correction technique for measuring respiratory impedance through an endotracheal tube.
نویسندگان
چکیده
Measurement of respiratory impedance (Zrs) in intubated patients requires corrections for flow-dependent resistance and air compression inside the endotracheal tube (ET). The purpose of this study was to test a new correction technique for these effects. We therefore studied 110 patients in two conditions: breathing normally (C1), or breathing through an ET placed at the mouth (C2). In C1, we measured pressure and flow signals at the mouth, and in C2, at the ET inlet, during application of a pseudorandom forced excitation (4-32 Hz). In C1, respiratory impedance was calculated directly as Z1. In C2, pressure data were first corrected for the flow-dependent resistance of the ET, and respiratory impedance was then corrected both for gas compression inside the set-up and ET inertance (impedance Z2). Strong linear relationships were found between the reference and corrected estimates of the resistance at 6 Hz, the frequency dependence of resistance and the resonant frequency. The mean normalized distance between Z1 and Z2 observed in the patients over the 4-32 Hz frequency range was about 14% for resistance and 12% for reactance (-9% and -4%, respectively, when considering the algebraic value of the distance). This slight underestimation of both components of impedance might be due to an overcorrection of pressure for the flow-dependent resistance of the ET. We conclude that, in intubated patients, newly tested corrections for the mechanical contribution of the endotracheal tube may yield a fair estimate of respiratory impedance when pressure is measured at the inlet of the endotracheal tube.
منابع مشابه
A Comparative Study of the Efficacy of Surfactant Administration through a Thin Intratracheal Catheter and its Administration via an Endotracheal Tube in Neonatal Respiratory Distress Syndrome
Background: The cornerstone of the treatment of respiratory distress syndrome (RDS) is respiratory support and surfactant replacement therapy. The administration of surfactant through a thin intratracheal catheter is one of the methods used to reduce one of the standard technique complications of a surfactant injection (Intubation-Surfactant-Extubation method [INSURE]). The aim of this study wa...
متن کاملNew Metal Shield for the Endotracheal Tube during Laser Endolaryngeal Surgery
Introduction: To present and assess a newly designed autoclavable, reusable tube shield for an endotracheal tube (ETT) during laser laryngeal surgery. Materials and Methods: This study included patients scheduled for endolaryngeal laser surgery. A carbonated stainless-steel hemisphere shield (~1.5×0.6 mm) connected to a silk thread passing through a hole in its middle near upper edge was ...
متن کاملRecording pressure at the distal end of the endotracheal tube to measure respiratory impedance.
To minimize the flow-dependent effects caused by an endotracheal tube during impedance measurements, we recorded pressure inside the tube at its distal end. We used a commercial endotracheal tube with a lumen built into its wall with the opening located near the outlet of the tube. We characterized the effect of the tube by means of an effective transfer function (H). We measured H from 0.25-32...
متن کاملThe Effects of Endotracheal Tube and i-gel® Supraglottic Airway Device on Respiratory Impedance: A Prospective Observational Study
BACKGROUND The forced oscillation technique (FOT) is a non-invasive means of measuring respiratory resistance and reactance. We tested our hypothesis that endotracheal intubation would cause more substantial preoperative increases in FOT parameters than a supraglottic airway device (SGD). METHODS Forty patients requiring general anesthesia and mechanical ventilation for transurethral bladder ...
متن کاملRespiratory system impedance from 4 to 40 Hz in paralyzed intubated infants with respiratory disease.
To describe the mechanical characteristics of the respiratory system in intubated neonates with respiratory disease, we measured impedance and resistance in six paralyzed intubated infants with respiratory distress syndrome, three of whom also had pulmonary interstitial emphysema. We subtracted the effects of the endotracheal tube after showing that such subtraction was valid. Oscillatory flow ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 9 5 شماره
صفحات -
تاریخ انتشار 1996